TYPICAL WIRING (continued)

Table 2. Wiring Requirements

Wiring

Type of Power

Transfer

(door to frame)

Maximum Wire

Length from Power

Supply to Power

Transfer

Minimum

Wire Gauge

Power Supply Input

Power Supply Output

(+24 and GND)

External Alarm, Fire Alarm,

Door Position Switch,

External Inhibit Device

EPT-10

EPT-10

Electric Hinge

Electric Hinge

EPT-10,

Electric Hinge

N/A

Per code

100 feet

200 feet

75 feet

150 feet

Per code

14 GA

12 GA

14 GA

12 GA

18-22 GA

Not critical

In this double door application, both doors open in the same direction and each is equipped with a Chexit. The two
Chexits are connected (ganged) by the gray (CM+) and violet (CM-) wires. (If not used, insulate these wires
separately.)
 When one Chexit is set into alarm, the other also goes into alarm, and both unlock after 15 seconds. A
fire alarm unlocks both doors at the same time. An external inhibit device also unlocks both doors at the same time.
After an external inhibit, the door that was used rearms 2 seconds after closing, and the unused door rearms after
the full rearm time. For proper operation, the rearm times of ganged Chexits must differ by at least 2 seconds.

Double Door Application

Wire Functions

Power 24 VDC

Common for NO output;
24 VDC, 1 A maximum

Normally open output;
closes during alarm

Communication line;
used to connect Chexits

Communication line;
used to connect Chexits

Fire alarm input;
0 VDC = fire,

24 VDC = no fire

Door position switch input;

0 VDC = door open,
24 VDC = door closed

External inhibit input;
0 VDC = Chexit inhibited,
24 VDC = Chexit active

Signal 24 VDC;
can be used to power

FA, DPS, and EI inputs

Power supply ground

Red

Blue

Brown

Violet

Gray

Yellow

Orange

Green

White

Black

+24

C

NO

CM-

CM+

FA

DPS

EI

S C

GND

The wiring requirements in Table 2

below must be followed.

IMPORTANT

!

+24

Power transfer

Power transfer

Cable to

Chexit

device

Cable to

Chexit

device

Red (+24)

Black (GND)

Blue (C)

Brown (NO)

Violet (CM-)

Gray (CM+)

Yellow (FA)

Orange (DPS)

Green (EI)

White (SC)

GND

_

+

Power

supply

output

Power supply

input

Red (+24)

Black (GND)

Blue (C)

Brown (NO)

Violet (CM-)

Gray (CM+)

Yellow (FA)

Orange (DPS)

Green (EI)

White (SC)

FIRE

Figure 3. Wiring Connections, Double Doors

Summary of Contents for Chexit CX33A/35A

Page 1: ...ety and security needs as well as all requirements of NFPA101 for Special Locking Arrangement and UBC Special Egress Control Devices The Von Duprin Chexit device sounds an alarm and keeps an exit door secured for 15 seconds following an attempt to exit The Chexit releases immediately upon a fire alarm condition PUSH UNTIL ALARM SOUNDS DOOR CAN BE OPENED IN 15 SECONDS CX Rim Exit Device CX98 99 sho...

Page 2: ...onents you use in Table 1 3 Determine the physical location of each component used see Figure 1 4 Pull field wiring between component locations and frame side of power transfer see Figure 1 5 Mount components and connect them to field wiring see Figure 2 or Figure 3 6 Connect field wiring to frame side of power transfer Route wires through frame back box 7 Install frame back box and frame side of ...

Page 3: ...blue and brown wires separately Required Connect orange wire to white wire Connect green wire to white wire Use door loop or electric hinge Required Von Duprin PS873 Highly recommended Optional Required Optional wire multiple external inhibit devices in series Optional FIRE Used Yes Yes Table 1 Installation Components TYPICAL WIRING Figure 2 Wiring Connections Single Door Blue C Black GND Red 24 B...

Page 4: ... used rearms 2 seconds after closing and the unused door rearms after the full rearm time For proper operation the rearm times of ganged Chexits must differ by at least 2 seconds Double Door Application Wire Functions Power supply 24 VDC Common for NO output 24 VDC 1 A maximum Normally open output closes during alarm Communication line used to connect Chexits Communication line used to connect Che...

Page 5: ...box Install door back box 5 8 dia 3 Connect cable wires to same color power transfer door side wires Install door side of EPT 10 shown or finish installing electric hinge 4 Slide module into cover plate as shown 1 Remove end cap end cap bracket and cover plate from Chexit device End cap bracket Cover plate End cap Support hinge end of mechanism case while end cap bracket is not installed CAUTION ...

Page 6: ...odule and slide cover plate half way into mechanism case Make three connections shown Mechanism case 7 Solenoid connectors Position solenoid connectors as shown Pull cable slack behind module while slowly sliding module in Push cable connector away from cover plate while sliding past end of mechanism case 5 Install key cylinder if available otherwise continue with step No 6 Red plastic plate bevel...

Page 7: ...green and white wires 2 If external inhibit not used connect green and white wires together Red LED does not light Power not reaching Chexit Replace reset AC fuse circuit breaker check power supply input output voltages check input voltage at Chexit cable connector Red LED on solid then flashes fast and horn sounds 1 Pushpad pressed 2 Pushpad switch disconnected 1 Release the pushpad 2 Connect pus...

Page 8: ... switch is used the Chexit arms 2 5 seconds after the door closes 6 If you are using a door position switch but you want the full rearm time to expire before the Chexit arms call Von Duprin at 1 888 371 7331 and get instructions from Electrical Technical Support 7 For proper operation the rearm time of each ganged Chexit must differ by at least 2 seconds Location of Chexit option switches OPTIONS ...

Reviews: