911352_00(5)  Page 7  of 8

OPERATION

The operation of a Chexit with a door position switch is the same as described in the summary table, but:

The Chexit enters Armed mode 2.5 seconds after the door position switch contacts close.

If the door is held open and rearm time expires, the Chexit goes into Alarm mode.

When in Armed mode, the Chexit goes into Alarm mode if the door position switch contacts open.

The basic function of a Chexit is to sound an alarm and keep an exit door secured for 15 seconds following
an attempt to exit. Test the operation of your Chexit by performing actions Nos. 1 through 6 in the summary
below. Make sure your Chexit matches the descriptions in the summary. If it does not, see “Troubleshooting.”

TROUBLESHOOTING

Turn Chexit off, then back on, using key switch. Compare Chexit operation with the following table to
identify problems and solutions. After troubleshooting, re-test Chexit using steps under “Operation.”

Symptom

Red LED flashes fast and
horn sounds

Problem

Fire alarm contacts open

1. External inhibit contacts open

2. External inhibit function not used

and wires not terminated properly

Red LED flashes once

Solution

Connect normally closed fire alarm contacts
between yellow and white wires

1. Connect normally closed external inhibit

contacts between green and white wires

2. If external inhibit not used, connect green and

white wires together

Red LED does not light

Power not reaching Chexit

Replace/reset AC fuse/circuit breaker;
check power supply input/output voltages;
check input voltage at Chexit cable connector

Red LED on solid then flashes fast
and horn sounds

1. Pushpad pressed
2. Pushpad switch disconnected

1. Release the pushpad
2. Connect pushpad switch connectors (see step

No. 6 of “Installation”)

Red LED on solid then flashes
fast, horn sounds, and solenoid
pulls in for one second (two
sharp sounds)

1. Door open
2. Door position switch contacts

open

3. Door position function not used

and wires not terminated properly

1. Close door
2. Connect normally closed door position switch

contacts between orange and white wires

3. If door position switch not used, connect

orange and white wires together

Action

1. Turn on Chexit with key switch

(turn key clockwise)

Mode

Pushpad

Red LED

Alarm

Duration

Rearm

Unlocked

On solid

Off

Rearm time

(0-28 seconds)

Summary of Chexit Modes

2. Rearm time expires

3. Press pushpad

4. 15 second release delay expires

Armed

Release delay

Alarm

Unlocked

Locked

Locked

Slow flash

Fast flash

Fast flash

Off

On

On

Continuous

15 seconds

Continuous

5. Turn off keyswitch or activate

EI (external inhibit)

Inhibit

Unlocked

Off

Off

R

eturns to rearm mode

when key switch turned

on or EI reset

6. Fire alarm contacts open

Alarm

Unlocked

Fast flash

On if option switch

No. 8 is off

Continuous (turn off key

switch to clear)

Summary of Contents for Chexit CX33A/35A

Page 1: ...ety and security needs as well as all requirements of NFPA101 for Special Locking Arrangement and UBC Special Egress Control Devices The Von Duprin Chexit device sounds an alarm and keeps an exit door secured for 15 seconds following an attempt to exit The Chexit releases immediately upon a fire alarm condition PUSH UNTIL ALARM SOUNDS DOOR CAN BE OPENED IN 15 SECONDS CX Rim Exit Device CX98 99 sho...

Page 2: ...onents you use in Table 1 3 Determine the physical location of each component used see Figure 1 4 Pull field wiring between component locations and frame side of power transfer see Figure 1 5 Mount components and connect them to field wiring see Figure 2 or Figure 3 6 Connect field wiring to frame side of power transfer Route wires through frame back box 7 Install frame back box and frame side of ...

Page 3: ...blue and brown wires separately Required Connect orange wire to white wire Connect green wire to white wire Use door loop or electric hinge Required Von Duprin PS873 Highly recommended Optional Required Optional wire multiple external inhibit devices in series Optional FIRE Used Yes Yes Table 1 Installation Components TYPICAL WIRING Figure 2 Wiring Connections Single Door Blue C Black GND Red 24 B...

Page 4: ... used rearms 2 seconds after closing and the unused door rearms after the full rearm time For proper operation the rearm times of ganged Chexits must differ by at least 2 seconds Double Door Application Wire Functions Power supply 24 VDC Common for NO output 24 VDC 1 A maximum Normally open output closes during alarm Communication line used to connect Chexits Communication line used to connect Che...

Page 5: ...box Install door back box 5 8 dia 3 Connect cable wires to same color power transfer door side wires Install door side of EPT 10 shown or finish installing electric hinge 4 Slide module into cover plate as shown 1 Remove end cap end cap bracket and cover plate from Chexit device End cap bracket Cover plate End cap Support hinge end of mechanism case while end cap bracket is not installed CAUTION ...

Page 6: ...odule and slide cover plate half way into mechanism case Make three connections shown Mechanism case 7 Solenoid connectors Position solenoid connectors as shown Pull cable slack behind module while slowly sliding module in Push cable connector away from cover plate while sliding past end of mechanism case 5 Install key cylinder if available otherwise continue with step No 6 Red plastic plate bevel...

Page 7: ...green and white wires 2 If external inhibit not used connect green and white wires together Red LED does not light Power not reaching Chexit Replace reset AC fuse circuit breaker check power supply input output voltages check input voltage at Chexit cable connector Red LED on solid then flashes fast and horn sounds 1 Pushpad pressed 2 Pushpad switch disconnected 1 Release the pushpad 2 Connect pus...

Page 8: ... switch is used the Chexit arms 2 5 seconds after the door closes 6 If you are using a door position switch but you want the full rearm time to expire before the Chexit arms call Von Duprin at 1 888 371 7331 and get instructions from Electrical Technical Support 7 For proper operation the rearm time of each ganged Chexit must differ by at least 2 seconds Location of Chexit option switches OPTIONS ...

Reviews: