Starting Using the Start/Stop Panel
Press the starter button for each engine. Release the
button as soon as the engine has started. If you start
from a secondary station, the starter key at the main
control station must be in the ignition ON engine OFF
position. Stop cranking if the engine does not start
within 20 seconds.
If a station is active and locked, the engine(s) can only
be started from that station.
EVC engines are equipped with an auto-crank feature.
Pressing the start button will cause the engine to con-
tinue to crank for up to 5 seconds or until the engine
starts. Should you need to stop cranking, simply press
the stop button.
NOTICE!
Risk of starter damage, do not run the starter
for extended periods (>20 sec.). Allow time to cool
between start attempts.
Starting
68
47706354 08-2015 © AB VOLVO PENTA