101
6. Engine will not stop
CAUSE
●
TAMD71B: Fuel shut-off valve fuse defective (see
page 72 for changing fuse)
●
One of the semi-automatic fuses in the terminal
box has tripped (see page 71 for instructions on
resetting fuses)
●
Poor contact/open-circuit in wiring (loose connec-
tions, oxidation)
●
Key switch malfunction
●
Faulty stop relay*
●
Faulty solenoid valve (fuel shut-off valve)**
* TAMD63 and TAMD73WJ have no stop relay.
** TAMD73P and TAMD74 have no fuel shut-off valve.
REMEDY
Replace fuse (8A)
Reset the fuse by pressing in the button
Rectify any open-circuits/loose connections. Check
for oxidation on the contacts. If required, clean and
spray connection with damp-inhibitor spray. See the
wiring diagrams on pages 74– 89.
Replace key switch
Replace stop relay (or swap temporarily with start
relay)
Contact an authorized Volvo Penta service mechanic
7740156 - Downloaded from www.volvopenta.com 22/07/2009 00:44:08