background image

Walk Test
It takes about 60 sec for sensor to warm up after power is supplied. The purpose 
of walk test is to check and adjust the detection coverage at the installation of 
sensor. Set Time VR knob to “Test”, and then conduct the walk test. Pay attention 
to the walking direction in the walk test. The sensor is more sensitive to movement 
across the detection range and less sensitive to movement directly towards it. The 
load will switch ON for 3 sec for each movement detected, and switch OFF for 2 
sec before next trigger. Set the Time VR knob to the desired setting after walk test. 
When using IR remote control to enter Test mode, it will exit Test mode after 10 
min. The sensor LED indicator will stay ON during the warm up period. For remote 
controllable models, the sensor LED indicator will blink during the warm up period 
if the sensor has previously been programmed via remote control..

Usage of Lens Shield
Undesired detection areas can be shielded off by fixing the enclosed lens shield 
onto the lens. Trim the lens shield with scissors either horizontally or vertically until 
the desired detection area is obtained.

TROUBLE SHOOTING

1. Unit will not function at all/Lights won’t turn on
    - Check wiring to make sure that you have correct AC power at the unit.
   - Check the wiring from the unit to the source of power to make sure you have  
        wired the unit correctly.
    - Check the ambient light control to see if it was set at your desired level.
2. Detector clicks but does not work
    - Check if lamps are broken.
    - Check if lamps are tight in lampholders.
3. Lights go on and off quickly
    - Ensure light and heat are not being reflected onto the detector. Check for white  
       or reflective surfaces that may be causing the problem.

Summary of Contents for IMS64-2

Page 1: ...Installation Guide VOLTEX IMS64 2 Dual output indoor flush mount PIR motion detector IMS64 2 II112918 SL ...

Page 2: ...0W Halogen Max 850W Fluorescent or LED Max 300W Load 2 T2A T2B for HVAC Dry contact not controlled by Lux setting Max 3A normally open contacts 12 250VAC or 5 30VDC Environmental Protection Sensor IP23 from below when installed Operating Temperature 20 C 45 C Lens shield x 1 Detector x 1 Instruction manual x 1 Power box x 1 Plastic plug x 2 Wood screw x 2 ...

Page 3: ...eight of 2 5m Time Adjustment Time 1 for Load 1 with 7 steps adjustable 30s 1m 5m 10m 20m 30m TEST FIG 1 Time 2 for Load 2 with 7 steps adjustable 10s 1m 5m 10m 20m 30m 60m FIG 2 The sensor LED indicator will flash 3 times every time the VR knob is adjusted and the desired step is successfully selected PRODUCT DESCRIPTION OPERATION AND FUNCTION Detector Power Box Ø76 00 41 0 58 5 62 0 130 80 59 80...

Page 4: ...ectrical equipment must be carried out by qualified electricians Contact a qualified electrician in the event of fault or break down A circuit breaker 250VAC 10A type C according to EN60898 1 of load 1 T1 must be installed in the fixed wiring for protection A circuit breaker 250VAC 6A type C according to EN60898 1 of load 2 T2A T2B must be installed in the fixed wiring for protection If using powe...

Page 5: ...ing cable entry is suitable for cable size Ø2 5 4mm Trim the lower knockouts gradually by layer to reach the ideal space for cable size Ø5 10mm If more space is required please also trim upper knockout gradually by layer to reach the space up to Ø15mm Wiring Voltex Electrical 2018 All Rights Reserved A B C E D T2AT 2B N L T1 N L 220 240V Power Supply Load Load 8mm FIG 5 ...

Page 6: ...and keep the power cable outside Please strip off 6 8mm of cable sheathing for wiring FIG 6 2 Please refer to illustration of FIG 5 for correct wiring 3 Insert the power module into the ceiling first raise the two spring clips and insert the detector into the drilled hole on ceiling FIG 7 4 Detection range can be extended with additional slave sensors 5 Restore the power supply Drill a hole with 6...

Page 7: ...e models the sensor LED indicator will blink during the warm up period if the sensor has previously been programmed via remote control Usage of Lens Shield Undesired detection areas can be shielded off by fixing the enclosed lens shield onto the lens Trim the lens shield with scissors either horizontally or vertically until the desired detection area is obtained TROUBLE SHOOTING 1 Unit will not fu...

Page 8: ...ck the wiring diagram Adjust time to minimum and ensure unit is firmly fixed to a solid object with no moving branches etc in field of view Ensure detector is not being activated by stray moving heat sources such as heating outlets Fit the lens shield to eliminate triggering outside detection field Reduce the sensitivity level 5 Detector goes on under windy and rainy conditions Adverse weather con...

Reviews: