Lux Adjustment:
With 7 steps adjustable (for Load 1 only): 10-100-300-500-1000-2000 lux- (Day
Mode) (FIG.3)
•
Load 2 is independent and not controlled by Lux setting.
•
The sensor LED indicator will flash 3 times every time the VR knob is adjusted and
the desired step is successfully selected.
Sens Adjustment:
(For Time 1 & Time 2): approx. 25% ~ 100% (FIG.4)
•
Adjust sensitivity to suit the location and avoid false triggering
●
Please disconnect power completely and read the entire instruction manual
carefully before installation.
●
Installation and assembly of electrical equipment must be carried out by
qualified electricians. Contact a qualified electrician in the event of fault or
break down.
●
A circuit breaker (250VAC, 10A) type C according to EN60898-1 of load 1 (
↓
/
T1) must be installed in the fixed wiring for protection.
A circuit breaker (250VAC, 6A) type C according to EN60898-1 of load 2
(T2A,T2B) must be installed in the fixed wiring for protection.
●
If using power tools, ensure that they are set to a low torque setting.
Test Function
Under Test mode the load will switch on for 3 sec to each detection, and switch off
for 2 sec before next detection. Under Test mode the Lux setting is deactivated.
Day Mode Function
Under Day Mode the sensor can operate regardless of brightness level.
for T1
for T1 & T2
INSTALLATION AND WIRING
FIG. 1
FIG. 2
FIG. 3
FIG. 4