background image

 

8. 

REMOTE TERMINAL FOR AUTOMATIC / MANUAL OUTPUT ON-OFF CONTROL 

 

1. 

The DC-DC Converter can be set to control the output Manually or Automatically. 

2. 

Application of the Remote Control Terminal: 

 
 

A.  The converter can be set to manual control of the output via external switch   

 

 

B.  The remote On/Off function can be controlled via many types of On/Off switches and with various 

DC sources between 8V-32V. 

 

 

3. 

Once the Remote Terminal has been connected to a positive 8-32V, the converter will be modified to

 

Remote Control Mode and will remain in this mode until it is disabled either by reset   

, or to 

factory preset 

. See section 11 and 12 for more detail information.

 

 

Summary of Contents for VC-4820

Page 1: ...4 3V Bulk and 13 6V Float charge 3 3 digit LED display for displaying Voltage Current Operation Mode and Protection Fault Diagnosis 4 Remote Control Terminal for Manual or Automatic On Off control of...

Page 2: ...rger mode 4 SET button 5 INPUT OUTPUT CONTROL AUXILARY TERMINALS VIEW Remote Remote Terminal for Automatic Manual control of Output On Off 12V 0 5A Always On Auxiliary Output GND Ground terminal NC No...

Page 3: ...6 Wiring Diagram 6 1 Connection Diagram 1 Example 1 Example 2 Example 3...

Page 4: ...epeat step 4 to get to programmable mode again 6 Each short press will increase the output voltage setting by 0 2V steps 15 0V CHA Charger Mode And then back to 12 0V as shown in the following cycle c...

Page 5: ...control of the output via external switch B The remote On Off function can be controlled via many types of On Off switches and with various DC sources between 8V 32V 3 Once the Remote Terminal has be...

Page 6: ...ter and charger mode Battery is fully charged when the output float voltage is 13 6V and the current to the battery is less than 1Amp Remote Voltage Sensing Voltage converter can be finely tuned to su...

Page 7: ...rge Quick press the SET button to display charging Voltage and Current Please note that when the battery is full and the float charge current is less than 1A the current display shows 11 DISPLAY INDIC...

Page 8: ...e display for another 5 minutes 15 ALWAYS ON AUXILIARY OUTPUT The DC DC Converter will provide constant 12V 0 5A to power critical devices such as security or alarm and will supply a positive voltage...

Page 9: ...and restarts at 14 6V F03 Over Load Protection Self restart When the Output current is 2 Amp higher than 20A the unit will shut down the output The unit will self restart once the output current fall...

Page 10: ...20A Float Charge 13 6V Remote Control of Output ON OFF Yes Automatic or Manual Control Remote Voltage Sense Yes External Alarm Output 13 5V 0 25A To power warning device when the input is under volta...

Reviews: