9.
GENERAL OPERATION
LED Display
During operation, the LED display will display sequentially Voltage and Amps.
A quick press of the SET button will either hold the display (at desired V, A) or return to the default scrolling
mode.
The display will switch off after 5 minutes to conserve the energy. Display can be restarted by a quick press
of the SET button.
When the output current is less than 1 Amp or output is open circuited the LED display will show
indicating Low Output Amp. This applies to both converter and charger mode.
Battery is fully charged when the output float voltage is 13.6V and the current to the battery is less than
1Amp.
Remote Voltage Sensing
Voltage converter can be finely tuned to supply your device with the required voltage even when your device
is at a distance. You can use the remote voltage sensing terminals (S-, S+) to ensure accurate voltage is
supplied to the load.
Alarm Terminal
The Alarm terminal is for input low voltage alert (F05). It provides 12V, 0.25A to power remote LED to give
out alarm before the converter falls into low voltage protection mode and shuts down. The alarm signal will
turn On when the input is below 42V and will turn Off when the input rises back above 50V.