6.2  Connection Diagram 2 
 

 
7. 

INITIAL SET UP AND CONNECTION 

 

1. 

Leave the output terminals disconnected. 

2. 

Connect a 48V battery to the input terminals.   

 

DOUBLE CHECK FOR CORRECT POLARITY BEFORE CONNECTION. 

3. 

Programming Procedure using the SET button 

4. 

Press and hold the SET button until shows up and display flashes. 

5. 

Flashing digits indicate unit is in programmable mode. 

 

Otherwise repeat step 4 to get to programmable mode again. 

6. 

Each short press will increase the output voltage setting by 0.2V steps-> 15.0V -> CHA (Charger Mode).

 

And then back to 12.0V as shown in the following cycle chart. 

 

 

6. 

Stop at the desired Output Voltage or at the 

  if you select to set to battery charger mode. 

7. 

After few seconds, the display will stop flashing to confirm the selected setting.

 

The unit will then               

operate in new set voltage output or as a battery charger. 

8. 

Now you can connect the output terminals to a 12V device or to a 12V battery. Always double check for 
correct polarity.

 

 

Summary of Contents for VC-4820

Page 1: ...4 3V Bulk and 13 6V Float charge 3 3 digit LED display for displaying Voltage Current Operation Mode and Protection Fault Diagnosis 4 Remote Control Terminal for Manual or Automatic On Off control of...

Page 2: ...rger mode 4 SET button 5 INPUT OUTPUT CONTROL AUXILARY TERMINALS VIEW Remote Remote Terminal for Automatic Manual control of Output On Off 12V 0 5A Always On Auxiliary Output GND Ground terminal NC No...

Page 3: ...6 Wiring Diagram 6 1 Connection Diagram 1 Example 1 Example 2 Example 3...

Page 4: ...epeat step 4 to get to programmable mode again 6 Each short press will increase the output voltage setting by 0 2V steps 15 0V CHA Charger Mode And then back to 12 0V as shown in the following cycle c...

Page 5: ...control of the output via external switch B The remote On Off function can be controlled via many types of On Off switches and with various DC sources between 8V 32V 3 Once the Remote Terminal has be...

Page 6: ...ter and charger mode Battery is fully charged when the output float voltage is 13 6V and the current to the battery is less than 1Amp Remote Voltage Sensing Voltage converter can be finely tuned to su...

Page 7: ...rge Quick press the SET button to display charging Voltage and Current Please note that when the battery is full and the float charge current is less than 1A the current display shows 11 DISPLAY INDIC...

Page 8: ...e display for another 5 minutes 15 ALWAYS ON AUXILIARY OUTPUT The DC DC Converter will provide constant 12V 0 5A to power critical devices such as security or alarm and will supply a positive voltage...

Page 9: ...and restarts at 14 6V F03 Over Load Protection Self restart When the Output current is 2 Amp higher than 20A the unit will shut down the output The unit will self restart once the output current fall...

Page 10: ...20A Float Charge 13 6V Remote Control of Output ON OFF Yes Automatic or Manual Control Remote Voltage Sense Yes External Alarm Output 13 5V 0 25A To power warning device when the input is under volta...