CONFIGURATION

SERIAL PARAMETERIZATION TERMINAL

RS485 is used for transmitting information through the serial link in the VoltGuard system or for setting the RIO system 
parameters. The RIO system settings require a built-in serial terminal on the RS485 line. 

Connection

RS485 connection parameters:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9600, 8n1

The control terminal uses the RS485 interface in the semi-duplex mode. Once the power supply is on, the module 
automatically sends the basic menu. In case the terminal is connected after the power supply on the modules is on, the 
menu is sent immediately after ENTER is pressed again. 

Basic menu 

The basic menu enables the selection of four options. The selection is done by entering a number in square brackets 
and pressing ENTER. In case you select a wrong option, the menu is automatically displayed again. You can use this fea-
ture when the display terminal is not ready after the power supply is on, i.e. after pressing ENTER the menu is displayed 
again. The basic menu is displayed as follows:

----- DIO Terminal -----
[1] List digital inputs
[2] Slave settings list
[3] Change slave setting
[4] Save settings
Selection :

Option: [1] List digital inputs

The first option displays the way the processor interprets the digital inputs DIG_IN1 and DIG_IN2. In case the number 1 
is displayed, 230V/50Hz voltage is connected on the DIG_IN input. Once the values are listed, the basic menu is auto-
matically displayed. The option “List digital inputs” is displayed as follows:

Selection :1
> Digital input 1 state : 0
> Digital input 2 state : 1
----- DIO Terminal -----
[1] List digital inputs
[2] Slave settings list
[3] Change slave setting
[4] Save settings
Selection :

Option: [2] Slave settings list

The master module is planned to enable controlling several slave devices. The current implementation enables trans-
ferring the setting only for slave 0 through PLC communication. The communication protocol for PLC is prepared for 
slave type multi-node connections for future use. The option lists the setting for each slave and each input. This is 
displayed in two lines. The setting is then interpreted by the slave. The input settings are described in next chapter. The 
final list is displayed as follows:

Selection :2
> Slave 0, master input 1 controls : disabled and normal
> Slave 0, master input 2 controls : both and normal
> Slave 1, master input 1 controls : direct and normal
> Slave 1, master input 2 controls : direct and normal
> Slave 2, master input 1 controls : direct and normal
> Slave 2, master input 2 controls : direct and normal
> Slave 3, master input 1 controls : direct and normal
> Slave 3, master input 2 controls : direct and normal
> Slave 4, master input 1 controls : direct and normal
> Slave 4, master input 2 controls : direct and normal
> Slave 5, master input 1 controls : direct and normal

Summary of Contents for ShiftGuard

Page 1: ...dual Capacity Meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usually not installed between the input of the power supply poin...

Page 2: ...available current capacity so that the usual activities of the residents were not limited and the electric vehicle charging was not significantly delayed Or you can install the VoltGuard system that...

Page 3: ...available after stabilizer 3 Red True value read at IN2 input True value on DIGIOUT2 LED indicator on the device receives information on Log1 from the counterparty the state corresponds to the relay...

Page 4: ...he processor interprets the digital inputs DIG_IN1 and DIG_IN2 In case the number 1 is displayed 230V 50Hz voltage is connected on the DIG_IN input Once the values are listed the basic menu is auto ma...

Page 5: ...rminal 1 List digital inputs 2 Slave settings list 3 Change slave setting 4 Save settings Selection Option 3 Change slave setting This item in the menu enables setting the properties of logical 0 and...

Page 6: ...saving the master module setting to the internal memory This setting is then loaded once the power supply is on The result of the option is either ok or fail The result fail means the processor intern...

Page 7: ...communication cable The cables with a suitable cross section are connected according to the diagram in the chapter Connection diagram and LED indication Connection of RS485 line with HomeGuard Master...

Page 8: ...time for input change max 2 s RS485 communication Type RS485 twisted pair physical layer Communication line parameters 9600 baud 8n1 RS485 serial line power supply internal RS485 twisted pair replace...

Page 9: ...ot be operated with other voltage current or frequency than it was produce or professionally mod ified for The product must be placed and secured so that it is difficult to access or inaccessible for...

Reviews: