SAFETY INSTRUCTIONS

The product is capable of safe operation. The manufacturer warns of the risk of possible danger resulting from incor-
rect handling or incorrect use of the product:

¬

  The installation and maintenance must be carried out by a competent person with relevant electrical qualifications, 

who informs the operator about the conditions for safe operation.

¬

  The product must not be used for other than its intended purpose.

¬

  The product must not be modified compared to its standard design.

¬

  The product must not be operated with other voltage, current or frequency than it was produce or professionally mod-

ified for.

¬

  The product must be placed and secured, so that it is difficult to access or inaccessible for the people without any 

electrical qualification, especially children.

¬

  Before every re-commissioning, for example, after any reparation or maintenance, the protection and all safety meas-

ures must be completely restored to ensure safe operation.

¬

  The product must not be used in conditions and environments that do not guarantee safe operation (for example, 

installed on a flammable surface, its cover made of flammable materials, insufficient protection against foreign body 
intrusion or water and other liquid ingress).

In case the user does not comply with any of the above instructions and if this noncompliance results in any defect, the 
manufacturer disclaims any liability for the defect.

Summary of Contents for ShiftGuard

Page 1: ...dual Capacity Meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usually not installed between the input of the power supply poin...

Page 2: ...available current capacity so that the usual activities of the residents were not limited and the electric vehicle charging was not significantly delayed Or you can install the VoltGuard system that...

Page 3: ...available after stabilizer 3 Red True value read at IN2 input True value on DIGIOUT2 LED indicator on the device receives information on Log1 from the counterparty the state corresponds to the relay...

Page 4: ...he processor interprets the digital inputs DIG_IN1 and DIG_IN2 In case the number 1 is displayed 230V 50Hz voltage is connected on the DIG_IN input Once the values are listed the basic menu is auto ma...

Page 5: ...rminal 1 List digital inputs 2 Slave settings list 3 Change slave setting 4 Save settings Selection Option 3 Change slave setting This item in the menu enables setting the properties of logical 0 and...

Page 6: ...saving the master module setting to the internal memory This setting is then loaded once the power supply is on The result of the option is either ok or fail The result fail means the processor intern...

Page 7: ...communication cable The cables with a suitable cross section are connected according to the diagram in the chapter Connection diagram and LED indication Connection of RS485 line with HomeGuard Master...

Page 8: ...time for input change max 2 s RS485 communication Type RS485 twisted pair physical layer Communication line parameters 9600 baud 8n1 RS485 serial line power supply internal RS485 twisted pair replace...

Page 9: ...ot be operated with other voltage current or frequency than it was produce or professionally mod ified for The product must be placed and secured so that it is difficult to access or inaccessible for...