STATE REPLICATOR (RIO)

The Master modem is fitted with a pair of digital inputs replicated through PLC communication to the selected digital 
outputs (bistable relay) of the Slave modem. Using a serial parameterization terminal, you can set which input will 
be replicated on which output, or you can define that an input will be negated on a particular output. Once the power 
supply is on, the relay remains in the same state as without power and when communication is established the relay 
switches to the state corresponding to the particular input within few seconds. When communication is interrupted, the 
output relay switches to the state defined as the emergency state. Once communication is re-established, the output 
relay switches to the state corresponding to the particular input again. 

CONNECTION DIAGRAM AND LED INDICATION

Connection diagram:

 

RIO

 system LED indication

LED

LED

Master

Master

Slave

Slave

1 - Yellow

Input voltage available

Input voltage available

2 - Green

Voltage available after stabilizer

Voltage available after stabilizer

3 - Red

True value read at IN2 input 

True value on DIGIOUT2.  
LED indicator on, the device receives information on Log1 from 
the counterparty (the state corresponds to the relay state: ON/
OFF)

4 - Red

True value read at IN1 input

True value on DIGIOUT1. 
The LED indicator is on, the device receives information on Log1 
from the counterparty (the state corresponds to the relay state: 
ON/OFF)

5 - Blue

The internal system of status machine interruptions and timing running in the device. The LED indicator blinks, changes its state 
every 1 s.

6 - Blue

The device has sent the packet (the state change indicates 
sending) 

The device has received the packet (the state change upon 
receiving the packet).

7 - Red

In case the LED indicator is on or blinks, the device has initiated the peripheries and the processor started communicating with 
the modem 

  The LED indicator is on: DIO sends status information about the digital inputs and rewrites the Switch data on the output – the 

DIO device receives the data through the RS485 input line, encodes the data into the packet sent by PLC communication and 
writes the Switch data on the RS485 output. 

  The LED indicator blinks: a console running in the DIO device – the PLC packets transfer only status information about the digital 

inputs.

8 - Blue

OFF – the device is used as the Master digital input

ON – the device is used as the Slave digital output

Summary of Contents for ShiftGuard

Page 1: ...dual Capacity Meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usually not installed between the input of the power supply poin...

Page 2: ...available current capacity so that the usual activities of the residents were not limited and the electric vehicle charging was not significantly delayed Or you can install the VoltGuard system that...

Page 3: ...available after stabilizer 3 Red True value read at IN2 input True value on DIGIOUT2 LED indicator on the device receives information on Log1 from the counterparty the state corresponds to the relay...

Page 4: ...he processor interprets the digital inputs DIG_IN1 and DIG_IN2 In case the number 1 is displayed 230V 50Hz voltage is connected on the DIG_IN input Once the values are listed the basic menu is auto ma...

Page 5: ...rminal 1 List digital inputs 2 Slave settings list 3 Change slave setting 4 Save settings Selection Option 3 Change slave setting This item in the menu enables setting the properties of logical 0 and...

Page 6: ...saving the master module setting to the internal memory This setting is then loaded once the power supply is on The result of the option is either ok or fail The result fail means the processor intern...

Page 7: ...communication cable The cables with a suitable cross section are connected according to the diagram in the chapter Connection diagram and LED indication Connection of RS485 line with HomeGuard Master...

Page 8: ...time for input change max 2 s RS485 communication Type RS485 twisted pair physical layer Communication line parameters 9600 baud 8n1 RS485 serial line power supply internal RS485 twisted pair replace...

Page 9: ...ot be operated with other voltage current or frequency than it was produce or professionally mod ified for The product must be placed and secured so that it is difficult to access or inaccessible for...

Reviews: