TYPE DESIGNATION AND ORDER CODE

 
For a specific order code depending on the device features, contact the supplier or directly the manufacturer. 

ShiftGuard

SG xx yy. zz

HW modification
FW modification
Internal setting

INSTALLATION AND SOLVING OPERATIONAL PROBLEMS

MASTER AND SLAVE SETTING 

The selection if the unit is the Master or the Slave is done by the first switch on the DIP switch on the motherboard. The 
DIP switch can be accessed after the upper cover of the terminal block is removed. This setting should be done only by a 
trained installation technician. 

Address setting

The setting of the address makes sense only with the Slave unit. The setting is done by the last 4 switches on the DIP 
switch. In case the node is switched to the Slave mode, the setting console does not work. 

Example:
Master, setting console:  

01 00 00

Slave, communication, address 0:   10 00 00

DIN rail installation

The unit is mounted vertically onto the DIN rail in the switchboard. The device can be installed within the array of 
modular devices on the DIN rail like breakers and contactors. It is advisable to install the Master unit right next to the 
HomeGuard module and connect both units with a communication cable. The cables with a suitable cross-section are 
connected according to the diagram in the chapter “

Connection diagram and LED indication

”.

Connection of RS485 line with HomeGuard (Master) and PortGuard (Slave)

The ShiftGuard communication modules in the 

VoltGuard

 system are used for transmitting information on residual 

capacity, or for transmitting the status signals, typically information on the tariff. The connection is done through the 
RS485 line. The line is connected using a usual twisted pair; a suitable cable is, for example, Lam Flexo Twin communi-
cation cable or Lam Flexo FTP. With a cable length of hundreds of meters, it is advisable to consider terminating the bus 
by a termination resistor, usually up to 1000 ohms. However, it is not necessary in most cases as the bus communica-
tion speed is very low. 

Switching on and checking LED status indication

Switching on the device does not require any special procedure. It is enough to connect the device to the power supply. 
Once the device is switched on, it is advisory to check the LED status indication, see the chapter “

Connection diagram 

and LED indication

”. In case the device does not work, check if PLC_IN and PLC_OUT are on the same phase. The con-

nection to a different phase may work thanks to inductive coupling between the supply conductors. However, such a 
connection is unreliable. In case you cannot connect both nodes to the same phase, use the interfacial couplers (con-
tact the manufacturer) to establish the communication connection between the particular phases. 

Summary of Contents for ShiftGuard

Page 1: ...dual Capacity Meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usually not installed between the input of the power supply poin...

Page 2: ...available current capacity so that the usual activities of the residents were not limited and the electric vehicle charging was not significantly delayed Or you can install the VoltGuard system that...

Page 3: ...available after stabilizer 3 Red True value read at IN2 input True value on DIGIOUT2 LED indicator on the device receives information on Log1 from the counterparty the state corresponds to the relay...

Page 4: ...he processor interprets the digital inputs DIG_IN1 and DIG_IN2 In case the number 1 is displayed 230V 50Hz voltage is connected on the DIG_IN input Once the values are listed the basic menu is auto ma...

Page 5: ...rminal 1 List digital inputs 2 Slave settings list 3 Change slave setting 4 Save settings Selection Option 3 Change slave setting This item in the menu enables setting the properties of logical 0 and...

Page 6: ...saving the master module setting to the internal memory This setting is then loaded once the power supply is on The result of the option is either ok or fail The result fail means the processor intern...

Page 7: ...communication cable The cables with a suitable cross section are connected according to the diagram in the chapter Connection diagram and LED indication Connection of RS485 line with HomeGuard Master...

Page 8: ...time for input change max 2 s RS485 communication Type RS485 twisted pair physical layer Communication line parameters 9600 baud 8n1 RS485 serial line power supply internal RS485 twisted pair replace...

Page 9: ...ot be operated with other voltage current or frequency than it was produce or professionally mod ified for The product must be placed and secured so that it is difficult to access or inaccessible for...

Reviews: