78
After measuring, remove the test leads from the measured object and turn the
multimeter off.
11.10 Continuity test
Make sure that all objects that you wish to measure (including cir-
cuit components, circuits and component parts) are disconnected
and discharged.
Turn the multimeter on and select
measurement mode .
Press the “SELECT” button once
to switch to continuity test mode.
The continuity test symbol and the
Ω symbol appear on the display.
Press the key again to switch to the
next measuring mode.
Insert the red test lead into the Ω
measurement socket, the black
test lead into the COM measure-
ment socket.
If the measured resistance is equal
to or less than 50 Ω, the multimeter
will beep to indicate continuity. The
beeps stop when the resistance ex-
ceeds 50 Ω. The continuity test measures resistances of up to 1000 Ω.
“OL” (overload) indicates that the measuring range has been exceeded or that
the circuit is broken.
After measuring, remove the test leads from the measured object and turn the
multimeter off.