background image

16

Measuring spot size - Distance to Spot Ratio (D/S)

In order to obtain precise measuring results, the object to be measured must
be larger than the measuring spot of the IR thermometer. The measured
temperature is the average temperature of the measured area. The smaller the
object to be measured, the shorter the distance to the IR thermometer has to
be. The exact size of the measuring spot is indicated in the following diagram.
Furthermore, it is printed on the device. For precise measurements, the object
to be measured should be at least twice the size of the measuring spot. The
focus of the device is 914 mm. 

D/S ratio 50:1

unit: mm

Emission ratio

The emission ratio is a certain value which is used for describing the energy
emission characteristic of a material. The higher this value, the more radiation
a material can emit. This is indicated by means of the emission ratio. To obtain
accurate measuring values for different materials with the IR-1001A, an
emission ratio between 0.10 and 1.0 can be adjusted. Please find enclosed a
list containing the emission values of several materials.  

For compensation, the surface of shiny parts can be covered with adhesive
tape or matte black paint. It is not recommended to measure shiny materials or
metallic surfaces directly. 

The device cannot measure through transparent surfaces such as e.g. glass. It
will measure the surface temperature of the glass instead.

measuring distance

 

300

900

1500

middle of the

sensor beam

measuring 

 

laser beam

16mm

spot size

 sensor

13

stabilization to accommodate to the new ambient temperature before use. 

• Do not expose the device to high temperatures for a longer period of time. 

• Do not expose it to dusty and humid ambient conditions. Store the device in

the enclosed storing case after use in order to prevent contamination of the
lens. 

Laser warning!

Never point the laser either directly or (due to reflecting surfaces)
indirectly at the eyes. Laser radiation might cause irreparable
eye damage.  Deactivate the laser beam when measuring near
human beings. 

Operating elements

Display description

1. opening for IR sensor
2. laser outlet
3. LC display
4. Down key
5. Up key
6. Mode key
7. laser / background lighting

key

8. key for temperature 

measurement

9. handle

10. battery compartment

+

9

5

6

3

10

4

8

7

-

¡ ã

F

HOLD

¡ ã

C

SCAN

1

2

Summary of Contents for IR-1001A

Page 1: ...ehalten Copyright 2004 by Voltcraft Imprint These operating instructions are published by Voltcraft 92242 Hirschau Tel 0180 586 582 723 8 All rights including translation are reserved No reproduction...

Page 2: ...ur de mesure 2 539 1 000 C 3 0 de la valeur de mesure 5 3 Einf hrung Sehr geehrter Kunde mit dem Kauf eines Voltcraft Produktes haben Sie eine sehr gute Entschei dung getroffen f r die wir Ihnen danke...

Page 3: ...illante de l objet avec un ruban adh sif ou une peinture noire mate Il n est pas recommand de mesurer les surfaces brillantes ou m talliques en dirigeant le thermom tre directement sur celles ci L app...

Page 4: ...durchgelassene W rmestrahlung des Objektes und wandelt diese Information in einen Tempe raturwert um Temperaturmessung Zum Messen von Temperaturen richten Sie die ffnung des IR Sensors 1 auf das zu m...

Page 5: ...des avertissements suivants N utilisez pas l appareil proximit des appareils de soudure lectrique des 9 Mode Taster Funktion 6 Das IR 1001A misst w hrend jeder Messung folgende Tem peratur Werte Maxi...

Page 6: ...e 2 C 539 to 1000 C 3 0 of the measuring value 5 C 11 Introduction Dear customer Thank you very much for taking the excellent decision to purchase a Voltcraft product Voltcraft This name stands for ab...

Page 7: ...aining the emission values of several materials For compensation the surface of shiny parts can be covered with adhesive tape or matte black paint It is not recommended to measure shiny materials or m...

Page 8: ...ontains im portant information on the commissioning and handling of the product Please bear this in mind even if you pass it on to other people Please keep this operating manual for future reference L...

Page 9: ...weise 25 Fonction de la touche Mode 6 Le thermom tre IR 1001A d termine pendant chaque mesure les valeurs de temp rature maximum MAX minimum MIN la diff rence DIF et la moyenne AVG Ces valeurs sont m...

Page 10: ...t vos piles et accus usag s soit aupr s de nos succursales soit aupr s des d chetteries communales centres de tri de mat riaux recyclables qui sont dans l obligation de les r cup rer Contribuez la pro...

Page 11: ...warzer Farbe bedeckt werden Es wird nicht empfohlen gl nzende Materialien oder metallische Oberfl chen direkt zu messen Das Ger t kann nicht durch transparente Oberfl chen wie z B Glas messen Statt de...

Page 12: ...ant un produit Voltcraft vous avez choisi un produit d une qualit exceptionnelle ce dont nous vous remercions vivement Voltcraft Ce nom est en effet garant d une qualit au dessus de la moyenne dans le...

Page 13: ...emperature changes the device needs approx 15 minutes of 17 Mode key Function 6 The IR 1001A measures the following temperature values during each measuring maximum MAX minimum Min difference DIF and...

Page 14: ...n to environmental protection Function IR thermometers measure the surface temperature of an object The sensor of the device analyzes the emitted and reflected heat radiation of the object measured an...

Reviews: