INTENDED USE

The digital storage oscilloscope is intended for visually displaying electric measurements and signals. The 

probe heads connect via BNC plug.
Measured signals can be saved and displayed on the screen as reference. On-screen menus allow for 

controlling the device.
The max. input values which are shown on the device must not be exceeded. If necessary, use divider 

probe heads or attenuators.
The device must only be connected to and operated by an isolated ground receptacle of the public power 

grid.
Any other than the intended use described above might result in product damage and furthermore cause 

hazards such as short-circuit, fire, electric shock, etc.
The whole product must not be modified or rebuilt and the housing must not be opened.
Measurements in damp locations or outdoors or under adverse conditions are not permissible.
Adverse ambient conditions are defined as such:

 - wetness or excessive humidity,
 - dust and flammable gases, vapors or solvents,
 - thunder and lightning or similar conditions e.g. strong electrostatic fields, etc.

These brief instructions explain the safety precautions you should follow to make operating the device as 

safe as possible. The English operating instructions explain the individual functions of the device in detail. 

The instructions are available in the main directory on the CD provided. In addition to that, the oscilloscope 

also features a help menu (“Help” button).
All safety warnings in the quick start guide and operating instructions must be adhered too.

DELIVERY CONTENT

•  Digital storage oscilloscope
•  4x passive probe head 10:1
•  Grounding type mains cable
•  Software CD
•  English operating instructions on the software CD
•  Quick guide

DESCRIPTION OF SYMBOLS

The device left the factory in a safe and perfectly working technical condition.
To maintain this condition and ensure safe operation, the user must observe all safety instructions and 

warnings included in these instructions. Please observe the following symbols:

The exclamation mark within a triangle alerts the user to important information that must 

be adhered to.

The triangle containing a lightning symbol warns against danger of electric shock or 

impairment of the electrical safety of the device.

The arrow symbol alerts the user to the presence of important tips and notes on using 

the device.
This device is CE compliant and fulfills all applicable European guidelines. Warning! This 

is a class A equipment. The equipment can cause radio interference in residential areas; 

in such a case, the user can be asked to perform appropriate measures.

CAT I

Measurement category I for measurements on low-voltage signals and controls without 

high-energy discharging.

CAT II

Only in combination with passive probe heads:
Measurement category II for measurements on household appliances that are 

connected to the mains via mains plug. This category also includes all smaller 

categories (e.g. CAT I for measuring signal and control voltages).

Protective ground connection, safety class 1. This screw/connector must not be loosened.

Ground potential

Ground potential chassis

CH1- CH4

Measuring input (BNC socket)

Power switch: Pressed = I = On; Not pressed = 0 = Off

SAFETY INSTRUCTIONS

Please read the quick start guide and operating instructions before operating the device; 

they contain important information on the correct use.

•  Damage caused by non-observance of the instructions will void the warranty/guarantee. We 

are not liable for any consequential damage!

•  We are not liable for property damage or injuries caused by improper use or non-observance 

of safety instructions! Such circumstances will void the warranty!

•  Unauthorized modifications and/or alterations to the product are not permitted due to safety 

and approval reasons (CE).

•  The product design complies with Protection Class 1. Only use a proper, earthed wall socket 

(100 - 240 V~) of the public power grid as voltage supply.

•  The wall socket must be located near the device and be easy to access or it must feature an 

emergency cut-off mechanism.

•  Measuring devices and appliances operated via mains supply must be kept out of reach of 

children. Use extreme caution when children are present.

•  First connect the measuring cable to the oscilloscope and then connect the probe head to 

the signal measurement circuit to be tested. After measuring, first disconnect the measuring 

contacts from the measurement circuit and then disconnect the measuring cable from the 

oscilloscope.

•  Exercise extreme caution when handling voltages >50 V/AC or >75 V/DC! Even at such 

voltages you can receive a life-threatening electric shock upon contact with electric wires.

•  Always check the your meter and test leads for damage(s) before each measurement. Never 

conduct measurements if the protective insulation is damaged (torn, missing, etc.).

•  To prevent electric shock, make sure not to touch the connections/measuring points to be 

measured directly or indirectly during measurement.

•  When measuring, never reach beyond the tangible marking of the grip area on the probe. 

There is a risk of lethal electric shock!

•  Do not use the device shortly before, during or shortly after a thunderstorm (lightning! / 

high energy over voltage). Please make sure that your hands, shoes, clothing, the floor, the 

measuring device, test leads, switches, switching components, etc. are dry.

•  Do not use the device in rooms or under adverse conditions, in/under which inflammable 

gases, vapors or dusts are or might be present.

•  Avoid use in the direct vicinity of:

 - strong magnetic or electromagnetic fields
 - transmitting antennas or high-frequency generators.

Failure to do so may falsify readings.

•  Only use measuring leads or measuring accessories adjusted for the oscilloscope.
•  If a safe operation cannot be assumed any longer, the device must be decommissioned and 

be secured against accidental use. Safe operation is no longer guaranteed when:

 - the device is visibly damaged,
 - the device no longer works and
 - the device was stored for a long period of time under adverse conditions or
 - the device has been subjected to considerable stress in transit.

•  Never switch the product on if it has just been brought from a cold room to a warm room. The 

condensation generated could destroy the product. Leave the device turned off until it has 

reached room temperature.

•  Do not dismantle the product! There is a risk of lethal electric shock!
•  Do not leave packaging materials lying around, they may become a dangerous plaything in 

the hands of children.

•  The product is only suitable for use in dry indoor spaces only (no bathrooms or other wet 

rooms). Shield the device from becoming moist or wet. There is a risk of lethal electric shock!

•  For installations in industrial facilities, follow the accident prevention regulations for electrical 

systems and equipment of the government safety organization or the corresponding authority 

for your country.

•  In schools and training facilities and hobby and self-help workshops, the use of measuring 

devices must be monitored by trained and responsible personnel.

•  Consult an expert when in doubt about the operation, safety or connection of the multimeter.
•  Please handle the product carefully. It could get damaged due to impacts, blows or even 

falling from a short height.

Regularly check the technical safety of the device and test leads — i.e. auf for damages 

to the housing or pinching, etc. Never operate the device when open.
!RISK TO LIFE!
Never exceed the maximum permissible input values. Do not touch any circuitry or 

connection points when voltages exceeding 50 V/ACrms or 75 V/DC might be applied. 

Risk of fatal injury!
•  Never pull the mains plug from the socket by pulling at the cable. Always pull it from the 

mains socket using the intended grips.

•  Unplug the mains plug from the mains socket if you do not use the device for an extended 

period of time.

•  Disconnect the mains plug from the mains socket in thunderstorms for reasons of safety.

Summary of Contents for DSO-1074D

Page 1: ...snetzes verwendet werden Die Netzsteckdose muss sich in der Nähe des Gerätes befinden und leicht zugänglich sein oder es muss eine Not Aus Vorrichtung vorhanden sein Messgeräte und Geräte die an Netzspannung betrieben werden gehören nicht in Kinderhände Lassen Sie deshalb in Anwesenheit von Kindern besondere Vorsicht walten Schließen Sie das Messkabel zuerst an das Oszilloskop an bevor Sie den Tast...

Page 2: ...schließen installieren Sie zuerst die Messsoftware 2 Schalten Sie Ihren Computer ein und starten das Betriebssystem 3 Legen Sie die beiliegende Software CD in das CD Laufwerk ein und schließen es Der Autostart Modus startet automatisch die Installation der Messsoftware Erfolgt dies nicht automatisch so führen Sie manuell das Programm setup exe auf der eingelegten CD ROM aus Die Installation der So...

Page 3: ...with Protection Class 1 Only use a proper earthed wall socket 100 240 V of the public power grid as voltage supply The wall socket must be located near the device and be easy to access or it must feature an emergency cut off mechanism Measuring devices and appliances operated via mains supply must be kept out of reach of children Use extreme caution when children are present First connect the meas...

Page 4: ... computer and start the operating system 3 Insert the software CD provided into the CD drive and close it The auto start feature will automatically start the installation of the software If not manually run the setup exe file on the inserted CD ROM The installation of the software will then start 4 Follow the on screen instructions 5 A new folder will be created in the file manager of the start me...

Page 5: ...a construction et ou de transformer le produit La construction du produit correspond à la classe de protection 1 Comme source de tension seul une prise réseau réglementaire reliée à la terre 100 240 V du réseau électrique d alimentation public doit être utilisée La prise réseau doit se trouver à proximité de l appareil et doit être facilement accessible ou il doit y avoir un dispositif de débranch...

Page 6: ...gnal Après avoir effectué la mesure retirez le cordon de mesure de l objet mesuré et éteignez l appareil INSTALLATION DU LOGICIEL DE MESURE 1 Avant de connecter l oscilloscope à un ordinateur installez d abord le logiciel de mesure 2 Allumez votre ordinateur et démarrez le système d exploitation 3 Insérez le CD du logiciel fourni dans le lecteur de CD et refermez le Le mode de démarrage auto comme...

Page 7: ... van het product valt onder veiligheidsklasse 1 Gebruik alleen een schone geaarde contactdoos 100 240 V van de openbare elektriciteitsnet als voedingsspanning De contactdoos moet zich in de buurt van het apparaat bevinden en eenvoudig bereikbaar zijn of moet van een uitschakelmechanisme in geval van nood voorzien zijn Houd meetinstrumenten en apparaten die via de netvoeding van stroom voorzien wor...

Page 8: ...er eerst de meetsoftware 2 Schakel de computer in en start het besturingssysteem 3 Breng de meegeleverde CD ROM in het CD station en sluit het De automatische startfunctie start automatisch met het installeren van de software Als dit niet het geval is open het setup exe bestand op de ingebrachte CD ROM handmatig De software wordt vervolgens geïnstalleerd 4 Volg de aanwijzingen op het scherm 5 Er w...

Reviews: