77
¼
If the current value blinks, you can switch between manual (“Man”) and automatic
(“Aut”) mode by simultaneously pressing the buttons “INC” and “DEC”.
In manual mode (“Man”), the batteries are charged with the current you have set.
In automatic mode (“Aut”), the charger calculates the charge current automatically;
all you do is set the top limit for the charge current. Shorter charging times can be
achieved depending on the battery and its internal resistance.
• Change the charge current (or in automatic mode the top limit for the charge current)
using the buttons “INC” and “DEC”, confirm the value using the “ENTER/START” button.
The number of cells is automatically identified!
• To begin the charging process, keep the “ENTER/START” button pressed for longer
(approx. 3 seconds).
• If the charger detects an error (e.g. no battery connected), a warning signal is emitted
and a corresponding info appears on the display.
You can stop the warning signal by pressing the “TYPE/STOP” button. You then return
to the previous configuration menu.
• If the battery is detected correctly, the following display appears, for example:
Battery type
Charge current Battery voltage
Current charging duration Charge capacity in mAh
• Once the charging process has been completed, an audio signal is emitted.
¼
If you wish to terminate the charging process beforehand, press the “TYPE/STOP”
button.
NiMH 2.0A 7.42V
NiMH 2.0A 7.42V
NiMH 2.0A 7.42V
NiMH 2.0A 7.42V
NiMH 2.0A 7.42V
CHG 043:20 01253
CHG 043:20 01253
CHG 043:20 01253
CHG 043:20 01253
CHG 043:20 01253
Summary of Contents for B6 Duo
Page 18: ...18 10 MENÜSTRUKTUR ...
Page 69: ...69 10 MENU STRUCTURE ...
Page 120: ...120 10 STRUCTURE DU MENU ...
Page 171: ...171 10 MENUSTRUCTUUR ...
Page 206: ...206 ...
Page 207: ...207 ...