34
The following functions are available:
Depending on the set battery type (LiPo, LiIo, LiFe, LiHV, NiMH, NiCd, Pb), different setting functions are
available. For example, the setting function for the charge end voltage per cell is only available for lithium
rechargeable batteries.
Therefore, always set the rechargeable battery type first and only then the other data, so that the charger
can offer the matching setting functions.
Rechargeable battery type
For this, select the rechargeable battery type "LiPo", "LiIo", "LiFe", "LiHV", "NiMH", "NiCd" or "Pb".
As described above, this selection must be made first, since the right setting functions are only displayed
then.
Battery voltage
Depending on the set rechargeable battery type, the rechargeable battery voltage can be set here.
However, it is not possible to set any voltage, but the steps depend on the rated voltage of an individual cell
of the respective rechargeable battery type; see chapter 7.
For example, the rated voltage of a cell in LiPo rechargeable batteries is 3.7 V; the rechargeable battery
voltage can thus only be set in steps of 3.7 V (3.7 V, 7.4 V, 11.1 V, etc.).
Charging current
Set the desired charging current here. It must be selected according to the rechargeable battery used.
Charging channel 1 offers a charging current of max. 20.0 A, charging channels 2 and 3 a charging current
of max. 10.0 A. Observe that the charging output of the charger limits the maximum possible charging cur-
rent; also see chapter 9. d).
Discharging current
Set the desired discharging current here. It must be selected according to the rechargeable battery used.
The discharge output of the charger for channel 1 is max. 25 W, and for channel 2 and 3 it is max. 10 W
each.
BATT TYPE
LiPo
BATT VOLTS
7.4V( 2S)
CHARGE CURRENT
2.2A
DSCH CURRENT
1.2A