31
• If the value for the charging current must be changed, push the "START/ENTER" button. The charging current
flashes. Change the charging current using the buttons "INC." and "DEC.". Keep the respective button pressed for
quick adjustment.
• Confirm the set charging current with the "START/ENTER" button.
The maximum possible charging current depends on the cell number and the max. charging output of the
charging channel used.
• To begin the charging process, keep the "START/ENTER" button pressed for longer (approx. 3 seconds).
If the settings are wrong, or if the charger detects a problem, an audio signal is emitted and the appropriate
information is shown on the display. You can stop the warning signal by pressing the "BATT. TYPE/STOP"
button. The charger then returns to the previous configuration menu.
The display shows, e.g., the following data while charging:
The rechargeable battery type is shown in the upper left ("Pb" = lead bat-
tery), as well as the cell number; the upper middle shows the charging cur-
rent and the upper right the current rechargeable battery voltage.
The lower left shows the current rechargeable battery programme ("CHG" = "CHARGE"), in the middle the elapsed
charging time and the charged capacity in mAh are displayed to the right of this.
• Once the charging process has been completed, an audio signal is emitted (if it was not turned off).
If you wish to cancel the charging process, push the "BATT. TYPE/STOP" button.
c) Discharging Battery ("DISCHARGE")
To put partially charged lead batteries into a defined starting condition, they can be discharged with this rechargeable
battery programme.
The rechargeable battery can also be used to measure the capacity of rechargeable batteries.
The maximum possible discharging current depends on the battery type, battery capacity and number of
cells. The max. discharge output of the charger for channels 1 is 25 W, and for channels 2 and 3 it´s 10 W
each. This limits the max. possible discharge current for rechargeable batteries with multiple cells.
Proceed as follows to discharge a lead battery:
• First, choose the rechargeable battery type "Pb BATT" with the buttons "INC." and "DEC." as described in chapter
13. a) and push the button "START/ENTER".
• Select the corresponding rechargeable battery programme "DISCHARGE"
with the buttons "INC." or "DEC.".
The set rechargeable battery type is shown in the upper left of the display,
and the rechargeable battery programme next to it.
The value on the lower left shows the currently set discharging current, the value on the right shows the voltage or
number of cells of the lead battery (in this example, a 6-cell lead battery (6 x 2.0 V = 12.0 V)).
Use the buttons "INC." and "DEC." to select a different rechargeable battery programme; use the button
"BATT. TYPE/STOP" to return to the main menu.
P-6 3.0A 12.59V
CHG 022:45 00980
Pb DISCHARGE
0.1A 12.0V(6P)
Summary of Contents for 1528380
Page 1: ...Operating Instructions Multifunctional charger V Charge 300 Triple Item No 1528380 ...
Page 46: ...46 ...