Wallbox 

eVolve

Series

Instruction Manual

Summary of Contents for S

Page 1: ...Wallbox eVolve Series Instruction Manual ...

Page 2: ... this manual can be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties athat may result from its use All ot...

Page 3: ... 2 Features 3 How to use it 4 How to configure it 5 3G Communications 6 Integrations 7 OCPP 1 5 8 Monitoring 9 Technical Data 10 Need help Here s your guide to use and configure eVolve 02 04 06 08 20 24 26 34 38 40 ...

Page 4: ...formance from it with step by step configuration instructions ATTENTION Indicates that the damage to property can occur if appropiate precautions are not taken 1 THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT SAFETY INFORMATION IN THIS DOCUMENT Complies with IEC 61851 Electric vehicle conductive charging system IES 61851 1 and IEC 61851 22 Complies with IEC 62196 Plugs socket outlets vehicle coupler...

Page 5: ...r country Do not make repairs or manipulations with the unit energised Only trained and qualified personnel should have access to electrical parts inside the device Check the installation annually by a qualified technician Remove from service any item that has a fault that could be dangerous for users broken plugs caps that don t close Use only Circontrol supplied spare parts Do not use this produ...

Page 6: ...04 Wallbox eVolve Series Instruction Manual 2 4 1 1 Display 3 Plug A LED Beacon 2 Proximity Card Reader 4 Plug B LED Beacon A B CIRCONTROL 3 2 ...

Page 7: ... Ethernet TCP IP communication for remote supervision and configuration 3G Modem optional For those places where wired communications are not sufficient Energy metering Integrated meter built is measuring power and energy consumed by the EV during a charge transaction Remote access For supervision and control from everywhere Charge transaction historics Charge Point is capable of storing informati...

Page 8: ...e and the Display shows the following sequence of messages 2 Plug the cable to the vehicle choose one available socket in case there are more than one and plug the cable to the Charge Point Once done the Display shows the following sequence of messages If the proximity card reader is disabled charge transaction starts automatically when a vehicle is detected ...

Page 9: ... Green and the Display shows the summary of the charge transaction 2 Unplug the cable from both sides Once done the connector becomes available and the Display shows the following sequence of messages If the proximity card reader is disabled charge transaction stops automatically when a cable is disconnected from the vehicle ...

Page 10: ...ences or specific setup using integrated Ethernet communication port allocated in the main controller device B What s needed Before proceeding with the configuration make sure all the following is ready Computer running Microsoft Windows at least Windows XP UTP Cable Crossover recommended IPSetup exe Software provided by Circontrol ...

Page 11: ...ss from a DHCP server available on the network Connecting a PC directly with the Charge Point needs to be done with static IP address The PC and the Charge Point must be in the same network and in the same range C Connection In order to change the IP of the Charge Point use IP Setup Enter the MAC of the device Enter the desired IP Address Click on Configure ...

Page 12: ... Manual D Setup web page Setup web page allows managing networking setup modem 3G setup upgrading the device and other options To access the setup web page open a web browser and enter the following address http IP ADDRESS html setup html ...

Page 13: ... DHCP Enable or disable the IP address assignment by a DHCP server DHCP Client ID Client ID associated to the DHCP Server If available Address IP address assigned to the charge point Netmask Netmask of the network This section provides basic configuration of the network parameters ...

Page 14: ... credentials are not needed insert 1234 on both fields Password Reset timer hours Timer to reset the modem and communications Ping IP IP address where the Charge Point pings Ping period minutes Period between pings Reset on ping failure Checked enabled Unchecked disabled For enabling 3G integrated modem check this section to set the parameters provided by the SIM Card network operator ...

Page 15: ...me must be entered manually in the Public IP text box SIERRA Wireless Raven XE H2295EW Select this option only when SIERRA Wireless RAVEN XE cellular router is connected to the charge point SIERRA Wireless AirLink LS300 Select this option only when SIERRA Wireless AirLink LS300 cellular router is connected to the charge point Embedded modem Select this option when using 3G integrated modem This se...

Page 16: ...on allows changing the language of the Display I Time setup Value Description Primary NTP Server Synchronize the time through internet auto matically Secondary NTP Server Time zone Select the regional unit time according to the location Time Current date and time of the unit This section allows setting the time and region unit time ...

Page 17: ...ption Server type Select the type of Dynamic DNS Server Hostname Parameters provided by dynamic DNS server User Password Server Port Dynamic DNS is a system that updates in real time the public IP address assigned to a domain name server ...

Page 18: ...Username and password authentication for setup html web page New password Repeat password Prevent unauthorised access to the setup web page All of the parameters are disabled by default factory settings Do not forget the credentials There is no way to reset the device to default factory settings It will require returning the unit to the service centre ...

Page 19: ...he unit Version Upgrade Version of the firmware currently installed and link to the upgrade web page Powerstudio version Engine version of PowerStudio Devices status Link that allows viewing the status of the configured devices This section provides basic information about the unit ...

Page 20: ... is provided by the service centre Firmware file transfer must not be interrupted Failure of the file transfer involves irreversible damage the main controller of the Charge Point It will require returning the unit to the service centre Ensure that the unit is not affected or powered off while updating Direct link http IP ADDRESS html upgrade html ...

Page 21: ...b page is a log that is created since charge point is powered ON If charge point is restarted this log is erased and immediately is created a new one Direct link http IP ADDRESS services chargePointsInterface log html ...

Page 22: ...n of the Setup web page refer to Section 4 for more information Once SIM card is inserted on the embedded 3G modem enter the following parameters APN Access Point Name User Password These parameters are provided by the network operator of the SIM card inserted A Parameters ...

Page 23: ...me that SIM card is inserted the Charge Point asks to enter its PIN number PIN number will not be required anymore after entering for the first time and the device will start 3G communications automatically After entering PIN number and clicking on Confirm button it shows the following confirmation message ...

Page 24: ...S html modem status html Value Description Connection 3G communications status Data access protocol used Signal and coverage IP Address Public IP assigned by the SIM card network operator Good signal Bad signal Moderate signal 80 dBm 90 dBm 50 dBm 100 dBm Following diagram shows an approximated range of signal strength that can be obtained depending on the location of the Charge Point ...

Page 25: ...23 ...

Page 26: ...eeding in order to ensure proper performance If 3G modem is enabled select Embedded Modem within Public Address Manager section Direct link http IP ADDRESS html setup html Select desired integration version according to your charge point operator Direct link http IP ADDRESS 65432 6 Before starting A ...

Page 27: ...it starts as configuration mode and all fields are empty The data is always saved even when the Charge Point is powered off In order to setting up the integration open a web browser and enter the following link http IP ADDRESS 8080 Use following credentials to access User admin Password 1234 ...

Page 28: ...lows the Charge Point to know where the central system is hosted to notify all the requests Following fields are mandatory to complete Value Description Host URL URL address of the central system User Authentication for central system Leave in blank if not needed Password ...

Page 29: ...col Require CS client certificate If HTTPS is selected make sure to have CS Server CA certificate Provided by the Central System OCPP Listening port Incoming listening port for remote request User for the CB server Authentication for central system Leave in blank if not needed Public IP timeout Maximum waiting time to obtain the public IP address of the 3G modem ...

Page 30: ...white list Yes local list of authorized users enabled No local list of authorized users disabled Authorization check order White list first ID authorization has first place on the local white list If the user does not exist locally then in second place backend is asked to obtain the authorization CS first ID authorization is always asked to the backend ...

Page 31: ...wed to start a new charge transaction Retry after CS internal error Yes Enabled If StatusNotification StartNotification or StopNotification are not delivered correctly to the backend Charge Point tries again to send those requests until it is successful No Disabled NOTE Special development must be done in backend in order to retry the messages by charge point Use OCPP time synchronization Yes Sync...

Page 32: ...rge if StartTransaction rejects the user Yes Stop existing charge transaction after response from backend StartTransaction conf when user is Blocked Expired or Invalid No Charge transaction does not stop even if backend rejects the user StartTransaction conf Set this option according to your backend system Stop charge if StartTransaction replies ConcurrentTx Yes Stop existing charge transaction af...

Page 33: ...er Power Active Import and energy Energy Active Import Register consumed by the vehicle within meter values requests No Only energy consumed is sent within meter values request Heartbeat interval Interval between Heartbeats in seconds for the Central System Connection timeout Timeout in seconds before connecting to the Central System Meter value sample interval Interval between Meter values in sec...

Page 34: ...l actions to complete the OCCP configuration Value Description Save Setup Save settings and apply changes Refresh Restore data entered Configuration Upload from file Export configuration into a single file Configuration View file Import configuration from a file ...

Page 35: ...33 ...

Page 36: ...34 Wallbox eVolve Series Instruction Manual 8 ...

Page 37: ...35 Monitoring Client A Charge Point status can be monitored using a software provided by Circontrol ...

Page 38: ...36 Wallbox eVolve Series Instruction Manual B Plug section This section describes the plug status and other useful information ...

Page 39: ...37 ...

Page 40: ...50 x 290 x 600 mm Large 450 x 290 x 850 mm ENVIRONMENTAL CONDITIONS Operating temperature 5ºC to 45ºC Operating temperature with Low Temperature Kit 30ºC to 45ºC Storage temperature 20ºC to 60ºC Operating humidity 5 to 95 Non condensing GENERAL DATA Display LCD Multi language Light beacon RGB Colour indicator RFID reader ISO IEC 14443A B MIFARE Classic Desfire EV1 ISO 18092 ECMA 340 NFC 13 56MHz M...

Page 41: ...6kW Depending on the model some components may vary For availability of models please consult your local supplier ELECTRICAL DATA Power supply 1P N PE 3P N PE Input voltage 230VAC 10 400VAC 10 Frequency 50Hz 60Hz Overcurrent protection MCB curve C Safety protection RCD Type A 30mA Type B Surge protection Transient surge protector IEC 61643 1 Class II CONNECTIVITY Ethernet 10 100BaseTX TCP IP Cellu...

Page 42: ...40 Wallbox eVolve Series Instruction Manual 10 ...

Page 43: ...41 Need help In case of any query or need further information please contact our Post Sales Department 34 937 362 940 34 937 362 941 ps support circontrol com circontrol com ...

Page 44: ...ve Series Instruction Manual CIRCONTROL WALLBOX EVOLVE SERIES INSTRUCTION MANUAL A comprehensive guide on how to use and configure your Wallbox eVolve V1 0 April edition 2018 CIRCONTROL S A ALL RIGHTS RESERVED R72 ...