14. TECHNICAL DATA
Display .............................................. 2000 counts (characters)
Measuring rate .................................. approx. 2 measuring operations/second
Measuring method V/AC, A/AC ........ arithmetic average
Measuring line length ....................... each approx. 80 cm
Measuring impedance ...................... ≥10 MΩ (V-range)
Current probe opening ...................... max. 30 mm
Measuring jacks distance ................. 19 mm
Automatic deactivation ..................... approx. 15 minutes, cannot be deactivated
Voltage supply .................................. 2x 1.5 V micro batteries (AAA, LR3 or same build)
Working conditions ........................... +5 °C to +31 °C (rel. hum. <80%)
..........................................................
+31 °C to +40 °C (rel. hum. <50%)
Operating height ............................... max. 2000 m
Storage temperature ......................... -20 °C to +60 °C (rel. hum. <80%)
Weight .............................................. approx. 230 g
Dimensions (LxWxH) ........................ 200 x 70 x 38 (mm)
Measuring category .......................... CAT III 600 V
Degree of contamination .................. 2
Measurement tolerances
Statement of accuracy in ± (% of r display error in counts (= number of smallest
points)). The accuracy is valid for one year at a temperature of +23 °C (±5 °C), and at a
relative humidity of less than 80%, non-condensing.
Summary of Contents for 1386328
Page 3: ...3...