background image

 

•   In schools, training centres, hobby and self-help workshops, the use of the measurement 

devices must be supervised in a responsible manner by trained personnel.

 

   If you have doubts about how the equipment should be operated or how to safely connect it, 

consult a trained technician.

 

•   Handle the product with care. The product can be damaged if crushed, struck or dropped, 

even from a low height.

 

   Regularly check the technical safety of the device and the measuring cables, e.g., 

for damage to the casing or pinching of the cables etc. The device may in no case be 

opened or used, if the covers have been removed.

 

  !RISK OF FATAL INJURY!

  

 Never exceed the maximum admissible input values. Never touch circuits or parts of 

circuits when they may contain voltages greater than 30 V/AC rms or 30 V/DC! Life 

threatening!

 

   If in doubt about how to connect the device correctly, or should any questions arise that are 

not answered in these operating instructions, please contact our technical service or another 

specialist.

PACKAGE CONTENT

•  Digital oscilloscope
•  USB Y cable
•  WLAN antenna (stick with oscilloscope)
•  Operating instruction

Up-to-date operating instructions:    

1.   Open  www.conrad.com/downloads in a browser or scan the displayed QR 

code.

2.   Select document type and language and enter the item number into the 

search field. After submitting the query you can download displayed records.

CONTROLS

1.  CH 1: BNC measurement input channel 1
2.  CH 2: BNC measurement input channel 2
3.  EXT.: External BNC trigger input; use the trigger menu to perform the settings 
4.  CAL: Calibration output 1 kHz/2 Vp-p square wave signal
5.  GND: Earth connection, reference potential
6.  On/Off button
7.  USB connection
8.  ANT: Antenna
9.  Displays:
  

 

Power indicator

  

 

Charging indicator for rechargeable battery

  

 

The battery has been fully charged

  

 

USB/WIFI indicator 

 

 

If the LED is blinking, the oscilloscope creates an individual WLAN hotspot

 

 

If the LED lights up, there is a USB connection with the PC

  

 

When a connection with a tablet / PC is active, signals will be sent

  

 

A connection with the tablet/PC via a WLAN network is active

10.  Easylink:  Push this button to reset the IDSO and to activate the WIFI connection mode

G

 OPERATING INSTRUCTIONS

SMART WIFI SCOPE 1070D

ITEM NO. 

INTENDED USE

The digital oscilloscope is intended to be used for visualising electrical magnitudes and signals. The 

measuring lead is connected to the oscilloscope via two BNC sockets.
The measured signals can be displayed on an Android device or Apple tablet via WLAN.
The oscilloscope features an integrated rechargeable battery that can be charged via the USB port.
This enables you to use the measuring device without power cable.
The maximum input variables indicated on the device must never be exceeded. 
Any use other than that described above could lead to damage to this product and involves risks such as 

short circuits, fire, electric shock, etc.
No part of the product may be modified or rebuilt, and the housing must not be opened.
Measurements are not permitted in damp rooms or outdoors, nor under adverse environmental conditions.
Adverse environmental conditions are:
-  Dampness or high air humidity,
-  dust and combustible gases, vapours or solvents,
-  thunderstorms or similar weather conditions such as strong electrostatic fields etc.
These operating instructions explain the safety measures that should be taken to make working with the 

device as safe as possible. The individual device functions are explained in more detail in the help menu 

in the APP. 
Always observe the safety instructions of these operating instructions or the help menu.
This product complies with the legal national and European requirements. All names of companies and 

products are the trademarks of the respective owners. All rights reserved.

SAFETY INSTRUCTIONS

 

 Please read through the quick guide carefully before using of the device. It contains 

important information on its correct operation.

 

 The warranty will be void in the event of damage caused by failure to observe these 

safety instructions! We do not assume any liability for any resulting damage!

 

 For damage to property or personal injury caused by inappropriate handling or disregard 

of the safety instructions, we do not assume any liability! The warranty will be void in 

such cases.

 

•   The unauthorised conversion and/or modification of the product is not permitted for safety and 

approval reasons (CE). Do not disassemble the product.

 

•   This product is not a toy. Therefore, be especially careful when children are around. 

 

•   First, connect the measurement cable to the oscilloscope. Then connect the probe to the 

signal measuring circuit to be tested. After finishing the measurements, first disconnect the 

measurement leads from the circuit before you disconnect the cable from the oscilloscope.

 

•  Be especially cautious when dealing with voltages exceeding >30 V (AC) or >30 V (DC)! Even 

at these voltages, there is a danger of fatal electric shock if you touch electric conductors.

 

•   Do not use the product inside of rooms, or in poor ambient conditions, where flammable 

gases, vapours or explosive dust may be present or are present.

 

  Do not use in the immediate vicinity of:

 

  -  strong magnetic or electromagnetic fields

 

  -  transmitting aerials or HF generators

 

  These can distort the measurement.

 

•   Only use measuring cables, or equipment, appropriate for the oscilloscope’s specifications 

when taking measurements.

 

•   If you have reason to assume that safe operation is no longer possible, disconnect the device 

immediately and secure it against inadvertent operation. Safe operation can no longer be 

assumed if:

 

  -  The device is visibly damaged,

 

  -  the device does not function anymore and

 

  -  the device has been stored under unfavourable conditions for a long period of time or

 

  -  it has been subjected to considerable stress during transportation.

 

•   Never switch the device on immediately after having taken it from a cold in to a warm environ-

ment. The condensation that forms might destroy your device. Allow the device to reach room 

temperature before switching it on.

 

   Never disassemble the product! There is risk of a life-threatening electric shock!

 

•   Do not leave packaging material carelessly lying around, since it could become a dangerous 

plaything for children.

 

•   The device is intended only for dry indoor locations (not for use in bathrooms or similar damp 

interiors). The device must not get wet or damp. There is risk of a life-threatening electric 

shock!

 

•   In commercial institutions, the accident prevention regulations of the Employer’s Liability 

Insurance Association for Electrical Systems and Operating Facilities are to be observed.

VERSION 05/16

1409505

Summary of Contents for 1070D

Page 1: ...widrigen Umgebungsbedingungen ist nicht zulässig Widrige Umgebungsbedingungen sind Nässe oder hohe Luftfeuchtigkeit Staub und brennbare Gase Dämpfe oder Lösungsmittel Gewitter bzw Gewitterbedingungen wie starke elektrostatische Felder usw Diese Bedienungsanleitung dient zur Erklärung der Sicherheitsvorkehrungen um das Arbeiten mit dem Gerät so sicher wie möglich zu machen Die einzelnen Gerätefunkt...

Page 2: ...n Sie das USB Kabel auf der einen Seite mit dem IDSO und auf der anderen Seite mit einem optionalen USB Netzteil 5 V 2 A 2 Verbinden Sie das USB Y Kabel auf der einen Seite mit dem IDSO und auf der anderen Seite mit zwei freien USB Ports an ihrem PC Laden Sie vor dem ersten Gebrauch den Akku vollständig auf INSTALLATION DER APP Gehen Sie in Ihren APP Store suchen die APP Voltcraft WIFI Scope und i...

Page 3: ...or similar weather conditions such as strong electrostatic fields etc These operating instructions explain the safety measures that should be taken to make working with the device as safe as possible The individual device functions are explained in more detail in the help menu in the APP Always observe the safety instructions of these operating instructions or the help menu This product complies w...

Page 4: ...f any damage contact our customer service CHARGING THE BATTERY You can charge the battery in two ways 1 Connect the USB cable to the IDSO on one side and to the optional USB power supply 5 V 2 A on the other 2 Connect the USB Y cable to the IDSO on one side and to two free USB ports of your PC on the other Charge the battery fully prior to first use INSTALLING THE APP Go to your APP store search f...

Page 5: ...les est interdite Les conditions d environnement adverses sont Présence d eau ou humidité atmosphérique élevée poussières et gaz vapeurs ou solvants inflammables orage et ou temps orageux ainsi que des champs électromagnétiques puissants etc Ce guide rapide explique les précautions de sécurité pour travailler en toute sécurité avec cet appareil Les fonctions individuelles de l appareil sont expliq...

Page 6: ...érieur masse de référence est connecté au potentiel de terre conducteur de protection Avant chaque mesure vérifiez que ni votre instrument de mesure ni les cordons de mesure ne sont endommagés N effectuez jamais de mesures si l isolation de protection est endommagée déchirée arrachée etc Veillez à ne pas toucher directement ou même indirectement les raccordements à mesurer points de mesure afin d ...

Page 7: ...eden zoals sterke elektrostatische velden enz In deze gebruiksaanwijzing worden de veiligheidsmaatregelen toegelicht die een veilig gebruik van het apparaat mogelijk maken De afzonderlijke functies van het apparaat worden in detail uitgelegd in het help menu in de app Volg de veiligheidsaanwijzingen in deze gebruiksaanwijzing of in de hulpmenu s te allen tijde op Dit product voldoet aan de nationa...

Page 8: ...n het apparaat uit en weer aan Het meetsignaal mag uitsluitend op de binnenste ader worden gelegd De buitenste ader referentiemassa is op het aardpotentiaal aardleiding aangesloten Controleer voor elke meting uw meetinstrument en de meetdraden op beschadiging en Voer in geen geval metingen door als de beschermende isolatie is beschadigd ingescheurd afgescheurd enz Om een elektrische schok te voork...

Reviews: