approx. 20 °C
0.247 M ω
- Switch hand multimeter
V.A.G 1526 to 200 K ω
approx. 60° C
approx. 120° C
48.8 K ω
7.4 K ω
Switch to resistance measuring range 20 K ω
Test step
V.A.G 1598/18
sockets
Test of
▪ Test conditions
- Additional operations
Specified value
Rectifying fault
13
20 + 65
Road speed
sender -G68-
▪ Ignition switched off
- Pull connector off
sender, repeat
measurement on
sender =>Page
min.
0.8 K ω
- Check wiring from
control unit to send‐
er according to cur‐
rent flow diagram
max.
0.9 K ω
14
21 + 66
Gearbox speed
sender -G38-
▪ Ignition switched off
- Pull connector off
sender, repeat
measurement on
,
Check wiring from
control unit to send‐
er according to cur‐
rent flow diagram
min.
0.8 Kω
- Renew gearbox
speed sender -
,
max.
0.9 K ω
Test step 15: Multi-function switch -F125-
- Pull connector off multi-function switch.
-> Connector pin assignment
1 - To Pin 63 of control unit connector
2 - To Pin 40 of control unit connector
3 - To pin Pin 1 of control unit connector (earth)
Golf 1998 ➤
Automatic gearbox 01M self-diagnosis - Edition 10.1997
4.3 - Test table