Selector lever lock solenoid -N110-
Open circuit/short to earth
Wiring open circuit or short to earth
Selector lever lock solenoid -N110-
defective
- Read measured value block
; display group number
005
01312
Drive train data bus
defective1)
no communication1)
Data bus wiring/connectors defec‐
tive
- Check data bus wiring and connec‐
tors using current flow diagram
1) One of these displays appears in addition to relevant component.
V.A.G 1551 print-out
Possible cause of fault
Rectifying fault
01314
Engine control unit
no communication
Data bus wiring/connectors defective
Fault in system: Engine
- Check Data bus wiring and connectors accord‐
ing to current flow diagram
Check engine control unit
=> Repair group 01 for relevant engine code
01316
Brake control unit
No communication
Data bus wiring/connectors defective
Fault in system: ABS
- Check Data bus wiring and connectors accord‐
ing to current flow diagram
Check ABS control unit
=> Repair group 01 for relevant ABS system
Output on printer
V.A.G 1551
Possible cause of fault
Rectifying fault
65535
Control unit defective
Control unit -J217- defective
- Initiate basic setting
The control unit -J217- should not be renewed until the possible cause of the fault has been determined and
the following faults have been rectified:
◆ mechanical faults
◆ hydraulic faults
◆ all affected electrical/electronic components and cable connections.
3.6 - Erasing fault memory
Requirement:
• Fault memory interrogated => page
.
After fault memory has been interrogated:
-> Indicated on display:
Rapid data transfer HELP
Select function XX
- Press keys 0 and 5. (The function "Erase fault memory" is entered with 05.)
-> Indicated on display:
Rapid data transfer Q
05 Erase fault memory
Golf 1998 ➤
Automatic gearbox 01M self-diagnosis - Edition 10.1997
26
01 - Self-diagnosis, Electrical check