1
Mynute 24m
Fig.1 General Layout
1
Flue Analysis Test Point
2
Pressure Tube Negative
3
Fan Assembly
4
Heat Exchanger
5
Combustion chamber
6
Burner
7
Expansion vessel
8
Transformer
9
Water pressure switch
10
Gas Valve
11
Time clock aperture (optional)
12
CH position
13
Fault indicator led
14
Mode selector switch
15
Pressure gauge
16
Safety valve
17
Pump
18
Auto air vent
19
Electrode
20
High limit thermistor
21
Primary thermistor
22
Air chamber (with cover removed)
23
Air pressure switch
The Vokera Mynute 24m is a central heating boiler, which
- by design- incorporates electronic ignition, circulating
pump, expansion vessel, safety valve, pressure gauge
and automatic by-pass.
It is produced as a room sealed, category II2H3+
appliance, suitable for wall mounting applications only. It
is provided with a fan powered flue outlet with an annular
coaxial combustion air intake that can be rotated -
horizontally - through 360 degrees for various horizontal
or vertical applications. The Mynute 24m can also be used
with the Vokera twin flue system.
This appliance is designed for use with a sealed system
only; consequently it is not intended for use on open vented
systems.
The provision of stored hot water is possible by the addition
of an indirect cylinder.
Fig. 1
INTRODUCTION