17
Fig. 21
4.7.3 CONNECTING THE MAINS (230V) INPUT (see
fi g. 21)
Locate and remove the terminal block cover (230V)
pressing clip
(A)
. Pass the supply cable fi rst through the
cable anchorage point and then through cable glands.
Connect the supply cable wires (LIVE, NEUTRAL, &
EARTH) to their corresponding terminals (L, N, & E)
on the appliance terminal block. When connecting the
EARTH wire, ensure that it’s left slightly longer that the
others, this will prevent strain on the EARTH wire should
the cable become taut.
4.7.4 CONNECTING THE PUMP (230V) OUTPUT (fi g. 21)
Pass the pump cable fi rst through the cable anchorage
point and then through the cable glands.
Connect the pump cable wires (LIVE, NEUTRAL, &
EARTH) to their corresponding terminals (Live = brown,
Neutral = blue, & Earth = green/yellow) on the appliance
terminal block. When connecting the EARTH wire, ensure
that it’s left slightly longer that the others, this will prevent
strain on the EARTH wire should the cable become taut.
Do not remove the link wire unless additional external
controls are to be fi tted (see section 8). The securing
screw on the cable anchorage should now be tightened.
This must be done before the control fascia is re-fi tted
in the upright position. The appliance casing and the
screws, can now be re-fi tted.
Fig. 20
cable glands