17
Fig. 17
link wire
ME3
ME6
4.7.3
CONNECTING THE MAINS (230V) INPUT (see
fig. 17)
Locate and remove the screw securing the right
terminal block cover (230V). Pass the cable
through the cable anchorage point.
Connect the supply cable wires (LIVE, and NEU-
TRAL) to their corresponding terminals on the
appliance terminal block. Connect the EARTH
wire to the EARTH block (see fig. 17) ensuring
that it’s left slightly longer that the others, this will
prevent strain on the EARTH wire should the
cable become taut.
Do not remove the link wire unless additional
external controls are to be fitted (see section 8).
The securing screw on the cable anchorage
should now be tightened. This must be done
before the control fascia is re-fitted in the upright
position. The appliance casing, screws, and lower
cover can now be re-fitted.