Potentiometer effects:
X0 -
With help of potentiometer X0 the minimum output pressure
P
A
min is adjusted at a setpoint of 4 mA.
Pressure increase by turning the potentiometer clockwise.
X1 -
With help of potentiometer X1 the maximum output pressure
P
A
max is adjusted at a setpoint of 20 mA.
Pressure increase by turning the potentiometer clockwise
X1 should be adjusted before X0.
The X1- adjustment influences the adjustment of X0.
Manufacturer-provided adjustments:
At the works, the
I/H converter has been adjusted as indicated in the
order.
7.
Operation
7.1
Operation with manual knob
Operation with manually controlled rotary knob is possible without electric
energy.
On operation with manually actuated rotary knob, uncontrolled stroke
movements of the hydraulic components controlled by the I/H converter
output might occur due to the increase in the output signal pressure.
Manual operation is only possible when the circlip is removed from the
manual operation knob.
On completion of operation with manual operation knob, move the
manual operation knob in its final position by turning it counter clockwise
and pushing in the circlip in its final position.
•
Remove the circlip.
•
Slowly turn the manual operation knob clockwise and observe the
output pressure.
Effective direction:
Output pressure increases by clockwise rotation.