![Voith 22000000700 Instruction Manual Download Page 5](http://html1.mh-extra.com/html/voith/22000000700/22000000700_instruction-manual_1044858005.webp)
Instruction Manual
Voith Turbo
Way Valve WSR-D16214
2005 / 03 aie
Voith Turbo GmbH & Co. KG
Page: 5 / 24
9183626018945 en
D – 74564 Crailsheim
Version: 2.0
Electrical Data
Supply voltage
24 (+10% / -15%)
V DC
Current consumption
1 A, max. 3 A for t < 1 sec
Electrical connection
See Chapter 10
Control Parameters
Setpoint w for stroke 0% … 100% w = 4.0 … 20.0 (load 155
Ω
) mA
Actual value input for stroke 0% ...
100%
20…4 (load 332
Ω
)
mA
Actual value remote indication for stroke
0% … 100%
4…20 (load 400
Ω
max.)
mA
Magnetic force switch-off at
w < 2
mA
Magnetic force switch-on at
w
≥
3
mA
Input configuration
E432 Electronics
E524 / Electronics
Applied, related to GND
Isolated (500 k
Ω
)
Setpoint limitation
E432 Electronics
E524 Electronics
E530 Electronics
w > 35
w > 20.2
w > 21
mA
mA
mA
Summary of Contents for 22000000700