5 Installation
Installation and operation of the way valve is only allowed for the conditions stated in
Chapter 1.
Do not install the way valve in an explosive atmosphere!
During operation, explosive atmosphere may get into the way valve via the tank.
Therefore, the hydraulic tank must not be set up in zone 0.
Only personnel satisfying the qualifications according to Section 2.3 are allowed to
work on the way valve.
Improper installation of the way valve may cause malfunctioning and premature failure
of the way valve.
Cleanliness is imperative during both installation and connection. Prevent any
impurities (dust, metal chips, etc.) from getting into the interior of the way valve or into
the piping system. Any such impurities may cause damage to the way valve.
During the installation period, cover and protect the way valve and, in particular, the
electric and hydraulic connections.
5.1 Mounting
All work may only be performed in de-energized condition and with the oil supply
system switched off. During installation, the oil and power supply for the product of
actuating system has to be secured against unintentional switching-on.
Mount the way valve according to the permissible installation position.
Recommended fastening bolts
2 socket head screws M12, ISO 4762, property class 8.8. Tightening torque MA = 80
Nm, thread oil-moistened. Select the screw length according to the installation
situation.