![Vogtlin red-y smart Series Instruction Manual Download Page 7](http://html.mh-extra.com/html/vogtlin/red-y-smart-series/red-y-smart-series_instruction-manual_1044492007.webp)
Title: Instruction manual PROFINET interface
Date: Sept. 2020
Ver: 04AD_Red-y_V2.1
By: WES/HAE
Page 7
/
30
Device network setup
The device comes with the following network settings:
Name
: “Red-y” or (“pnec-v1”)
IP address
: 192.168.0.50 or 0.0.0.0
The name and IP address can be changed using tools like
Proneta
(which can be downloaded from the
Siemens website www.siemens.com).
Tips:
Voegtlin uses following USB- to Ethernet Adapter:
D-Link DUB-E100
Status LED’s
The status LED’s are located on top of the device.
SYS – System status
Colour State
Description
On (green)
PROFINET Operating system running
Blinking (red/green)
PROFINET OS waiting for firmware
On (red)
PROFINET bootloader waiting for second stage loader
Off
Power supply missing or hardware failure
ERR – Bus status
Colour State
Description
Blinking (red)
No data exchange
On (red)
No configuration; or low speed physical link; or no physical link
Off
No error
RUN – Run status
Colour State
Description
Blinking (red)
DCP signal service is initiated via the bus
On (red)
Watchdog timeout; channel, generic or extended diagnosis
present; system error
Off
No error