P34AL-15 & P34Alof-15 Service Manual
TABLES & CHARTS
9/22/05
11-2
P34AL-15 SPECIFICATIONS, 400/460 Volt-3 Phase- 50/60Hz
Tube Size
inches
(cm)
1
(2.54)
1 1/4
(3.17)
1 1/2
(3.18)
Nominal Capacity
(1)
Tons/day
(M Tons/day)
63.8 (57.9)
59.6 (54.0)
45.3 (41.0)
Overall Dimensions (LxWxH)
Feet
(meters)
7x7x19’-1”
(2.1x2.1x5.8)
7x7x19’-1”
(2.1x2.1x5.8)
7x7x19’-1”
(2.1x2.1x5.8)
Shipping Weight
lbs
(Kg)
11,700 (5,307)
12,300 (5,579)
12,000 (5,443)
Operating Weight
lbs
(Kg)
15,400 (6,985)
16,200 (7,348)
16,100 (7,302)
Refrigerant Charge (R-717)
(2)
lbs
(Kg)
1,545 (700)
1,304 (591)
1,220 (553)
Total FLA
(3)
6.7 6.7 6.7
Maximum Fuse
15 15 15
Minimum Ampacity
7.8 7.8 7.8
System Requirements
- Dedicated Compressor
(4)
Tons
(KW)
121 (425)
112 (393)
101 (354)
- Average Refrigeration
(4)
Tons
(KW)
109 (383)
92.7 (325)
70.6 (247)
- Peak refrigeration
(4)
Tons
(KW)
145 (509)
130 (456)
80 (280)
-makeup
(5)
gpm
(m
3
/ Hr)
14.1 (3.8)
12.5 (3.4)
9.5 (2.6)
- blowdown per harvest
Galllons
(L)
50 (189)
50 (189)
50 (189)
Connection Sizes
-makeup water
FPT
1 1/2”
1 1/2”
1 1/2”
-tank drain
FPT
2” 2” 2”
-tank overflow
FPT
3” 3” 3”
-flush water
FPT
3/4” 3/4” 3/4”
-suction
Flanged
4” 4” 4”
-liquid feed
FPT/Socket
1” 3/4” 3/4”
-thaw gas
Flanged
2 1/2”
2”
2”
Compressor -HP-KW-FLA
Dedicated only
150 - 44.7 - 176
150 - 44.7 - 176
150 - 44.7 - 176
Water Pump -HP-KW-FLA
3 - 2.2 - 4.1
3 - 2.2 - 4.1
3 - 2.2 - 4.1
Cutter Motor -HP-KW-FLA
3 – 2.2 – 4.1
3 - 2.2 - 4.1
3 - 2.2 - 4.1
THR at Pulldown
Btu/hr
(kW)
2,126,000 (622)
1,798,500 (526)
1,369,000 (400)
(1) Nominal capacity is based on 70°F makeup water, 16
°
F suction temperature,100°F condensing temperature, 70°F ambient, and 25% blowdown.
(2) For evaporator only. Dedicated system charge is 1,000 lbs., (454Kgs).
(3) FLA for 460 volt models is approximately 1/2 that of 230 volt models. Total FLA does not include cooling tower or auxiliary equipment.
(4) Compressor Requirements is based on 16
°
F suction temperature,100°F condensing temperature, 70°F ambient, and 25% blowdown.
(5) Makeup water is maximum value and includes 25% blowdown. each cycle.
Vogt reserves the right to change designs and specifications without notice.
Table 11-1
Summary of Contents for P-34AL-15
Page 1: ...P 34AL 15 P34ALOF 15 TUBE ICE MACHINE Service Manual 5000 9 22 05 ...
Page 2: ......
Page 5: ...9 22 05 ...
Page 8: ......
Page 14: ...P34AL 15 P34ALOF 15 Service Manual TABLE OF CONTENTS vi ...
Page 19: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 5 FIGURE 1 2 P34AL 15 Right Side ...
Page 20: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 6 FIGURE 1 3 P34AL 15 Left Side ...
Page 22: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 8 FIGURE 1 5 P34ALOF 15 Right Side ...
Page 23: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 9 FIGURE 1 6 P34ALOF 15 Left Side ...
Page 24: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 10 ...
Page 50: ...P34AL 15 P34ALOF 15 Service Manual INSTALLING YOUR TUBE ICE MACHINE 9 22 05 3 24 ...
Page 62: ...P34AL 15 P34ALOF 15 Service Manual START UP OPERATION 9 22 05 5 8 ...
Page 88: ...P34AL 15 P34ALOF 15 Service Manual TROUBLESHOOTING 9 22 05 8 13 ...
Page 130: ...P34AL 15 P34ALOF 15 Service Manual Options and Accessories 9 22 05 10 16 ...
Page 131: ...P34AL 15 P34ALOF 15 Service Manual TABLES CHARTS 9 22 05 11 1 11 Tables Charts ...
Page 138: ...Appendix A ...
Page 141: ......
Page 143: ...i ...
Page 144: ...ii ...
Page 145: ...1 ...
Page 146: ...2 ...
Page 147: ...3 ...
Page 148: ...4 ...
Page 149: ...5 ...
Page 150: ...6 ...
Page 151: ...7 ...
Page 152: ...8 ...
Page 153: ...9 ...
Page 154: ...10 ...
Page 155: ...1 ...
Page 159: ...P24AL P34AL Service Manual INDEX 9 22 05 12 4 ...