P34AL-15 & P34ALOF-15 Service Manual
INSTALLING YOUR TUBE-ICE MACHINE
9/22/05
3-8
Water Tank Drain.
This valve and connection is for the purpose of flushing and draining the water
tank of impurities, foreign material and cleaning chemicals used during servicing. It should be piped
to an open drain or sump for visible discharge. It can be tied in with the overflow line but no others.
Water Tank Overflow.
A 3” FPT connection on the side of the water tank is provided to carry
away overflow water during the thawing (harvest cycle). This water contains ice fines accumulated
during harvesting and dissolved solids accumulated during the freezing cycle.
Do not reduce the
size of this line
. Three inches is needed to provide sufficient area for ice fines to be flushed out,
especially if the incoming flushing water is 55
°
F (13
°
C) or below. This overflow line should not tie
in with any other drain line except the water tank drain.
Unless water quality is superior, do not discharge the overflow water to the cooling tower system.
This water contains additional dissolved solids left from the ice making process and can lead to
excessive condenser fouling or cooling tower chemical usage. It is recommended that a heat
exchanger be used in place of direct contact with condenser water.
Receiver.
The receiver used to supply hot thaw gas must be sized adequately to provide sufficient
thaw gas. Table 3-2 shows the minimum volume required to hold the refrigeration charge of the
freezer and the hot gas required for the thaw cycle. It is recommended that a heating coil be
installed in the receiver to assure that the liquid ammonia is at saturated temperature at the start of
each thaw period. The receiver must be located inside a suitable building and must not be subjected
to ambient temperatures below 50
°
F (10
°
C) or above 110
°
F (43.3
°
C).
Note: Additional storage volume may be required for the interconnecting piping. Add volume of
interconnecting piping to the values shown in Table 3-2
RECEIVER VOLUME (Cubic Feet)
MODEL
With Heating Coil
With out Heating Coil
P34AL
60 80
TABLE 3-2
Receiver Volume Requirements
Thaw Gas Pressure Regulator.
The thaw gas pressure regulator is a 2 1/2” solenoid operated
pressure combination regulator and shut-off valve (see figures 1-1 and 1-4 for locations).
Do not
reduce the size of this line or connect to the compressor discharge piping
. This valve is
designed to carry the proper amount of thaw gas to the evaporator during the harvest cycle. See
Section 5-7 for operating instructions.
Suction Pressure Regulator. When a machine is attached
to a central refrigeration system a
pressure regulator will be required (see Figures 3-12 through 3-16 for location and general piping
arrangement). This regulator (usually furnished by the purchaser) must be a combination
backpressure regulating and stop type valve. The usual minimum pressure drop across this type
valve is 2 psig, therefore the valve must be set to maintain a freezer pressure at least 2 psi above the
maximum general suction pressure. For improved control during pull-down it is recommended that
a by-pass be installed around the suction regulator.
Compressor Unloading.
When a P34AL-15 is attached to a dedicated compressor system,
unloading of the compressor will be required. A minimum compressor unloading during the harvest
Summary of Contents for P-34AL-15
Page 1: ...P 34AL 15 P34ALOF 15 TUBE ICE MACHINE Service Manual 5000 9 22 05 ...
Page 2: ......
Page 5: ...9 22 05 ...
Page 8: ......
Page 14: ...P34AL 15 P34ALOF 15 Service Manual TABLE OF CONTENTS vi ...
Page 19: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 5 FIGURE 1 2 P34AL 15 Right Side ...
Page 20: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 6 FIGURE 1 3 P34AL 15 Left Side ...
Page 22: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 8 FIGURE 1 5 P34ALOF 15 Right Side ...
Page 23: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 9 FIGURE 1 6 P34ALOF 15 Left Side ...
Page 24: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 10 ...
Page 50: ...P34AL 15 P34ALOF 15 Service Manual INSTALLING YOUR TUBE ICE MACHINE 9 22 05 3 24 ...
Page 62: ...P34AL 15 P34ALOF 15 Service Manual START UP OPERATION 9 22 05 5 8 ...
Page 88: ...P34AL 15 P34ALOF 15 Service Manual TROUBLESHOOTING 9 22 05 8 13 ...
Page 130: ...P34AL 15 P34ALOF 15 Service Manual Options and Accessories 9 22 05 10 16 ...
Page 131: ...P34AL 15 P34ALOF 15 Service Manual TABLES CHARTS 9 22 05 11 1 11 Tables Charts ...
Page 138: ...Appendix A ...
Page 141: ......
Page 143: ...i ...
Page 144: ...ii ...
Page 145: ...1 ...
Page 146: ...2 ...
Page 147: ...3 ...
Page 148: ...4 ...
Page 149: ...5 ...
Page 150: ...6 ...
Page 151: ...7 ...
Page 152: ...8 ...
Page 153: ...9 ...
Page 154: ...10 ...
Page 155: ...1 ...
Page 159: ...P24AL P34AL Service Manual INDEX 9 22 05 12 4 ...