Installation & Start-up – HES Series
11
Piping and Drain Connections.
All connections are located at the rear of the machine. Water-cooled machines will have five
water connections (air cooled will have three water connections) on the freezing unit. See
FIGURE-7 to locate connections.
! CAUTION !
Exterior shut-off valves must be provided in the water inlet lines.
The minimum inlet water pressure for satisfactory operation of the machine is 30 psig.
The maximum allowable pressure is 100 psig.
! CAUTION !
Model
20
30
40
Make Up Water In
3/8” FPT
3/8” FPT
3/8” FPT
Water Tank Drain
3/4” FPT
3/4” FPT
3/4” FPT
Drip Pan Drain
3/4” FPT
3/4” FPT
3/4” FPT
Condenser Water In
3/4” FPT
3/4” FPT
1” FPT
Condenser Water Out
3/4” FPT
3/4” FPT
1” FPT
TABLE - 2
Water Supply and Drains
The condenser water outlet, water tank drain, drip drain and ice storage bin drain connections
must be extended to an open drain or sump and arranged for visible discharge. See FIGURE-7
for water and drain connections on machine. See FIGURE-8 of typical space diagram drawing
for ice storage bin drain connection.
! CAUTION !
These lines must NOT be connected into a pressure tight common header
due to the possibility that warm condenser water
may back up into the water pan, drip pan or the ice storage bin. The
condenser water outlet MUST be piped separately to the drain.
! CAUTION !
Note: Above drawing shown with plastic side casings (1/2” thick)
FIGURE –7
Water Connections
Summary of Contents for HE S Series
Page 2: ...Installation Start up HES Series 2 Blank Page ...
Page 12: ...Installation Start up HES Series 12 FIGURE 8 Typical Space Diagram ...
Page 26: ...Installation Start up HES Series 26 FIGURE 16 Piping Schematic Air Cooled ...
Page 27: ...Installation Start up HES Series 27 FIGURE 17 Piping Schematic Water Cooled ...