5
1. The stove must be placed on solid concrete, solid
masonry, or when installed on a combustible
ƀQQ
r,
on an Underwriters Laboratories Listed Type 2
ƀ
oor
protector listed to UL standard UL 1618, such as
Hy-C or Imperial Model UL4056BK. Floor protector
must be 1/
Ŋ
/13mm minimum thickness
(
R value
= 1.19, K value = 0.84
see page 23 for calculation
formulas) non-combustible material or equivalent.
The
ƀQQT
protector must extend at least
ŊEO
beyond the front of the access door,
ŊEO
to
the sides,
Ŋ
/21cm beyond the rear and must
extend under and
ŊOO
beyond either side of
the stove pipe if it is elbowed towards a wall. (See
ſIWTGU
5 – 7 and consult local building codes and
ſTGRTQVGEVKQPQTFKPCPEG
s.)
CAUTION: FIRE HAZARD. CARPETING AND
OTHER COMBUSTIBLE MATERIAL SHALL
NOT COVER THE FLOOR PROTECTOR. THESE
MATERIALS MUST REMAIN OUTSIDE OF COM-
BUSTIBLE CLEARANCES, SEE FIG. 5 – 7
2. The room in which the stove is installed must have
a minim
WOƀQQTVQEGKNKPIJGKIJVQHHV
. (2.4 m).
3. The stove must have its own
ƀ
ue. Do not con-
nect this unit to a chimney flue serving other
appliances. DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.
4. After observing the clearances to combus-
tible materials
ſIW
res 5 – 7), locate your
ƀ
oor
protector accordingly (figure 5) and careful-
.
n
o
it
a
c
o
l
d
e
t
c
e
l
e
s
r
u
o
y
n
i
e
v
o
t
s
e
h
t
e
c
a
l
p
y
l
Install connector pipe, elbows, and thimble as
required, utilizing either a recently cleaned and
inspected
ŊOO
lined masonry chimney or a
ŊOO
i.d. UL 103 HT (US)/ULC-S629 (CDN)
listed manufactured chimney.
5. Use round 6
Ŋ
/152mm dia., minimum 24 MSG black
or 26 MSG blue steel stove pipe to connect the
stove to the chimney. Do not use galvanized stove
pipe. Secure connector pipe to the
ƀWG
collar with
three (3) equally spaced sheet metal screws. Use
three screws in each stove pipe and/or elbow joint
to
ſ
rmly hold the pipe sections together. DO NOT
CONNECT THIS STOVE TO ANY AIR DISTRIBU-
TION OR DUCT SYSTEM.
6. Recheck clearances from the stove, con-
nector stove pipe, and cor ner clearanc -
es using the illustrations in figures 5 – 7 and
your local building codes or fire protection
ordinances.
NOTE: ANY WALL CONTAINING COMBUSTI-
BLE MATERIAL SUCH AS WOODEN STUDS OR
DRYWALL AND FACED WITH BRICK OR STONE
MUST BE CONSIDERED A COMBUSTIBLE
SURFACE.
7.
DO NOT install this stove in a mobile home,
Manufactured Home, Tent or trailer – NO
EXCEPTIONS!
(HUD Federal Standard: 24 CFR
Ch.xx)
8. T h e c l e a ra n c e s p r ov i d e d a r e m i n i mu m
dimensions set by US standard UL 1482-2011 &
ULC-S627-00, tested and applied by OMNI-Test
Laboratories, Inc. the manufacturer’s testing agency.
Installation of this stove must comply with the latest
edition of NFPA 211 (US)/CAN/CSA-B365 (CDN) for
reduced clearances and/or your local building code
rulings. Use whichever minimum dimensions are
LARGEST.
Clearances listed and shown MUST be adhered to
for safe operation of this appliance.
CLEARANCES
MAY NOT BE REDUCED BY ANY MEANS IN USA
OR CANADA
.
9. This stove meets U.S. Test Standard: UL 1482-
2011& Canadian Standard: ULC-S627-00.
are properly positioned and ash clean out cover
is in place.
13. Route the power cord away from stove. Do not
allow the power cord to touch any hot surfaces.
Keep power cord at least
Ŋ
from stove surfaces.
14. Once stove is positioned, plug power cord into a
grounded 120v outlet.
Figure 4 – Attach Optional
Blower to Stove Body
LOCATING STOVE
ASSEMBLY INSTRUCTIONS
LOCATING STOVE