2.

 

Precautions: 

 

Make  sure  you  have  all  necessary  tools  on  hand  before  you  begin  with  the 

installation. 

 

Follow all local legal regulations. 

 

Read  this  manual  carefully

.  If  you  have  any  questions  or  remarks,  please 

contact your evo-water supplier. 

 

Check incoming pressure: minimum 1 bar (dynamic), maximum  8 bar (static) 

(15 PSI – 116 PSI). If necessary reduce incoming pressure. 

 

Do  not  install  the  evo-water  softener  close  to  a  heating  source  (environment 

temperature must be below 40°C).  

 

Protect softener and drain (12) against frost. 

 

Make  sure  you  have  the  latest  installation  manual  at  hand.  Check  with  your 

evo-water supplier. 

 

3.

 

Installation: 

 

3.1

 

Close main valve and make sure pressure is released from piping. This can be 
done by opening at least one tap. 

 

3.2

 

Connect the two units by means of the provided Y-pieces. You can find them in 
the salt compartment. The Y-piece with the filter inside, needs to be mounted 

at the inlet of the valve. (= bottom connection) The other must be mounted at 
the other connection. 

 

First connect the Y-piece to one unit and afterwards to the other unit. Secure 
them with the provided clips (4 pieces). You don’t need to take the units out of 

the container to do this. 

 

 
 

 

 
 

 
 

 

 

Summary of Contents for duomatik evoline

Page 1: ...tener the installation guide has to be read carefully For any disturbances cause by disregarding the instructions evo water doesn t accept liability evo water oHG Falkenstra e 2 72589 Westerheim Tel 4...

Page 2: ...e protection of the central tax valves from rust sand etc a suitable mudflap or fine filter should be inserted before the arrangement The filter pad of the fine filters should be exchanged according t...

Page 3: ...OR 2 VALVE HOUSING 9 HARDNESS REGULATOR 3 RESIN TANK 10 TO BRINE VALVE 4 CONTAINER FOR DEVICE AND SALT 11 CONNECTIONS 1 2 3 4 1 5 BRINE VALVE float 12 TO DRAIN 6 WATER INLET 13 COMMUNICATION TUBES 7 W...

Page 4: ...and drain 12 against frost Make sure you have the latest installation manual at hand Check with your evo water supplier 3 Installation 3 1 Close main valve and make sure pressure is released from pip...

Page 5: ...ue dot 3 4 C u t o p e n m a i n w a t e r supply in order to install direct connections to the evo water Softener or to install the evo water Bypass recommended Follow the arrows on both Bypass and s...

Page 6: ...rain pipe is spirally reinforced to avoid later blocking and or kinks It is possible that both drains are connected with each other through a Y piece In this case connect the Y piece to the local drai...

Page 7: ...been drilled mount the overflow tap and secure it with the supplied nut After drilling remove all bits of plastic that have fallen into the container A separate instruction leaflet with detailed info...

Page 8: ...e no kinks in the tube and that the tube is not squeezed together Pay attention Watch carefully that you don t squeeze the tube when opening or closing the tilt drawer for the salt 4 Settings 4 1 Hard...

Page 9: ...setting 5 Start up 5 1 Leave Bypass in bypass mode open main valve and flush for several minutes in order to avoid impurities from entering the softener When you do not use a Bypass open the main val...

Page 10: ...ner This will happen only once at start up Once only water flows from the tap and no more air close the tap 5 6 Perform a manual regeneration 5 6 1 Choose one of both units to perform a manual regener...

Page 11: ...rm until it stops automatically The estimated time is approx 12 minutes When regeneration has stopped no more water flows to the drain This is a clear indication that the regeneration stage is over 5...

Page 12: ...fixed in the open position In this position you can easily refill the drawer with salt tablets When you are done refilling the salt just lift the cover a little bit and push the tilt drawer back in t...

Page 13: ...knowledge about hydraulic softeners and domestic plumbing Proper working of the softener will be determined by proper installation An annual control of your Softener will guarantee optimal functioning...

Reviews: