EGS-I&S-01

1

SINGLE-WALL INDIRECT

WATER HEATER

For your family’s comfort, safety, and convenience, we
recommend this water heater be installed and serviced
by a plumbing professional.

TABLE OF CONTENTS

IMPORTANT INFORMATION .................................. 1
GENERAL INFORMATION ....................................... 3
PRE-INSTALLATION .................................................. 4
WATER CONNECTIONS ............................................ 6
ELECTRICAL CONNECTIONS ................................ 8
OPERATING INSTRUCTIONS .................................. 8
MAINTENANCE ......................................................... 10
TROUBLESHOOTING GUIDE ................................ 12

IMPORTANT INFORMATION

The following terms are used throughout this manual to bring
attention to the presence of hazards of various risk levels,
or to important information concerning product life.

INSTALLATION & SERVICE MANUAL

 

WARNING

To avoid damage or injury, there must be no
materials stored against the indirect water heater
and proper care shall be taken to avoid unnecessary
contact (especially by children) with the indirect
water heater.

     

Do not store or use gasoline or other flammable

        liquids in the vicinity of this water heater or any
       other appliance.

The equipment must be installed in accordance with
those installation regulations required in the area
where the installation is to be made. These regulations
must be carefully followed in all cases. Authorities
having jurisdiction shall be consulted before
installations are made.

All wiring on water heaters installed in the USA must
be in accordance with the National Electrical Code and/
or local regulations; or in Canada, installed in
accordance with the Canadian Electrical Code and/or
local regulations.

 

DANGER

Indicates an imminently hazardous situation, which,
if not avoided, will result in death, serious injury, or
substantial property damage.

 

CAUTION

Indicates a potentially hazardous situation, which, if
not avoided, could result in death, serious injury, or
substantial property damage.

NOTICE

Indicates special instructions on installation,
operation or maintenance, which are important but
not related to personal injury hazards.

 

WARNING

Indicates a potentially hazardous situation, which, if
not avoided, may result in moderate, or minor injury
or property damage.

 DANGER

DO NOT store or use gasoline or other flammable,
combustible, or corrosive vapors and/or liquids in the
vicinity of this or any other appliance.

IF YOU SMELL GAS:

‰

DO NOT try to light any appliance.

‰

DO NOT touch any electric switch; do not
use any telephone in your building.

‰

Immediately call your gas supplier from a
telephone in another building.  Follow the
gas supplier’s instructions.

‰

If you cannot reach your gas supplier, call
the fire department.

DO NOT OPERATE THE APPLIANCE UNTIL
THE LEAKAGE IS CORRECTED!
Liquefied petroleum gas/propane gas is heavier than
air and will remain at floor level if there is a leak.
Basements, crawl spaces, closets, and areas below
ground level will serve as pockets for accumulation
of leaking gas.
This water heater is supplied with an adjustable
thermostat to control water temperature.  Hot water
temperatures required for automatic dishwasher and
laundry use can cause scald burns resulting in serious
personal injury and/or death. The temperature at
which injury occurs varies with the person’s age and
the time of exposure. The slower response time of
disabled persons increases the hazards to them.
NEVER
 allow small children to use a hot water tap
or to draw their own bath water.  NEVER
 leave a
child or disabled person unattended in a bathtub or
shower.

Summary of Contents for EGS-I&S-01

Page 1: ...njury or substantial property damage CAUTION Indicates a potentially hazardous situation which if not avoided could result in death serious injury or substantial property damage NOTICE Indicates special instructions on installation operation or maintenance which are important but not related to personal injury hazards WARNING Indicates a potentially hazardous situation which if not avoided may res...

Page 2: ...required for this water heater This water heater meets or exceeds the ASHRAE IES 90 1b standards with respect to insulation and standby loss requirements CAUTION The maximum boiler water supply temperature to the indirect heat exchanger must not exceed 240 F 116 C WARNING It is the responsibility of the installing contractor to see that all controls are correctly installed and are operating proper...

Page 3: ...Pressure Relief Valves and Vacuum Relief Valves The combination temperature and pressure relief valve must be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater The combination temperature and pressure relief valve must also have an hourly rated temperature steam BTU discharge capacity not less than the hourly rating of the water heater The supplied c...

Page 4: ...le formation Setting the water heater temperature at 120 F will reduce the risk of scalds Some states require settings to specific lower temperatures SACRIFICIAL ANODES Three sacrificial anode rods have been installed in the tank head to extend tank life The anode rods should be inspected annually to determine the amount of sacrificial decay and replaced when necessary to prolong tank life Water c...

Page 5: ...ot water demand is satisfied This option provides maximum delivery of domestic hot water Priority is recommended when a Boiler net output is 100 000 Btu per hour or less or b When boiler output required to satisfy domestic hot water demand is at least 50 of the boiler output required to satisfy space heating demand or c When an interruption in space heating can be tolerated during a long domestic ...

Page 6: ...Expansion Tank If the water heater is installed in a closed water supply system such as one having a back flow preventer in the cold water line provide thermal expansion control Contact the water supplier or local plumbing inspector for additional information MOVE THE WATER HEATER TO A PERMANENT POSITION BY SLIDING OR WALKING WATER CONNECTIONS WARNING FAILURE TO INSTALL AND MAINTAIN A NEW LISTED T...

Page 7: ... system Pipe and fittings between the boiler and Single wall Indirect must be diameter or larger CAUTION Maximum boiler water supply temperature to the indirect heat exchanger must not exceed 240 F 116 C Figure 1 Water Boiler Piping with Zone Valves Figure 2 Water Boiler Piping with Circulators 2 For a space heating system that utilizes CIRCULATORS refer to Figure 2 The Single wall Indirect connec...

Page 8: ...s shown and screw the aquastat clamp securely in the well groove The aquastat acts as a thermostat for zone control and should be wired accordingly Refer to the boiler or zone control manufacturer s instructions if any additional wiring is required The control is factory set at 120 F and care should be made to not rotate this dial while wiring the control Once electrical connections are complete s...

Page 9: ...g WATER TEMPERATURE ADJUSTMENT 1 The aquastat controls the maximum water temperature in the tank The differential is a fixed 5 F with a 160 F maximum setting set at the factory to 120 F Table 4 details the approximate relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the safest water temperature for your applications 2 For the most ene...

Page 10: ...ecommended size as necessary Do not attempt to repair the valve as this could result in improper operation and a tank explosion In areas with poor water conditions it may be necessary to inspect the temperature relief valve more often than once a year If the temperature pressure relief valve on the heater discharges periodically or continuously it may be due to thermal expansion of water in a clos...

Page 11: ...ater electricity on for the zone containing the Single wall Indirect 4 Sediment Annual but harsh water quality may dictate more frequent service Depending on water conditions a varying amount of sediment may collect in the tank Levels requiring service are indicated by a small temperature difference in the supply and return lines See also Scale below Repeated flushing usually clears such material ...

Page 12: ...r or Clean or replace filter or strainer boiler supply strainer if used Aquastat set too high Lower aquastat setting See Operating Instructions Improper system plumbing Compare to plumbing in Water Connections Improper system wiring Compare to wiring in Electrical Connections Aquastat setting too low Adjust aquastat to higher setting See Operating Instruction Undersized boiler with no Rewire for p...