VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
37
7.5
Automatic Shutdown and Restart
When an error is detected, the controls will automatically shutdown
the system, show and log the error that caused the issue.
Also, the system will shutdown if no air use is detected, and it has
idled for a preset amount of time. The system can be restarted by
using a large amount of air for a short time (air rate) or dropping of
air pressure below an adjustable value.
The LED beacon module will illuminate when the RAPTAIR MF is in
STANDBY mode and is able to restart when air-use is detected.
The buzzer module will enable and alert the operator before the
engine starts.
The system may automatically restart based on Air Usage Rate,
Restart Pressure, engine or compressor temperature or low battery
voltage.
7.6
Checking Messages and Errors
7.6.1
Errors
If an error is present, the RAPTAIR MF unit
WILL NOT
start the
compressor until the error is cleared. When an error is present the
WARNING LED will flash on/off and the screen will display
‘ERRORS DETECTED’ followed by the following list of errors. The
user MUST scroll through ALL the displayed errors by pressing the
NEXT button before the unit can re-try the start sequence.