7.7
Adjusting System Parameters
See section 7.4.6 for adjusting settings.
Below is a table of the adjustable settings accessible though the
display box diagnostics section.
SYSTEM PARAMETER TABLE
Setting
Description
Adjustment
Default
Unload Delay
Delay time to unload
0.5, 1, 2, 5, 10, 15,
30 minutes, Never
1 min
Standby Delay
Delay time to standby
1, 2, 5, 10, 15, 30
minutes, Never
5 min
System Pressure
Operating System
Pressure
80 to 150PSI @
5PSI increments
150PSI
Top-up Pressure
PSI below system
pressure to allow inlet to
open and build pressure
1 to 15PSI @ 1PSI
increments
10PSI
High Air Use Rate
Air rate set-point for
pressure-based restart
condition
0 to -30PSI @
0.5PSI increments
-3.0PSI/sec
Pressure Restart
PSI
Air pressure set-point for
pressure-based restart
80 to 150PSI @
5PSI increments
120PSI
Allow Cold
Engine Restart
Allow to restart the
engine if engine is
beginning to freeze
Enable/Disable
Enabled
Disable Auto
Restart Delay
Timer for disabling
automatic engine restart
Always, 30 min,
60 min, 120 min,
Never
60 min
Allow Low Battery
Restart
In Standby, allow the
engine to restart based
on low battery level
Enabled/Disabled
Enabled
Battery Restart
Lower Threshold
Engine will restart if
below this threshold for
30 seconds in Standby
10.0
– 14.0V @ 0.1V
increments
12.1V
Battery Restart
Upper Threshold
System will start duration
timer if above value
10.0
– 15.0V @ 0.1V
increments
12.8V
Battery Restart
Duration
Once above Upper
Threshold, stay running
for duration to charge
battery
1, 2, 5, 10, 15, 30
minutes
2 min