UF-216CC water Filtration system
8
A.J. Antunes & Co.
P/N 1011135 Rev. A 03/12
unpacking
1. Remove the system and all packing materials
from the shipping carton.
2. Remove all packing materials and protective
coverings from the system
3. Remove the information packet. To prevent any
delay in obtaining warranty coverage, fill out and
mail the warranty card.
nOte: If any parts are damaged, contact a.J.
antunes & co. ImmeDIately at 1-800-253-2991 or
1-630-784-1000.
InstallatIOn
plumbInG
nOte: this unit is designed to use tap water not to
exceed 100°f (38°c) or 100 psig (690 kpa).
The UF-216CC system uses the following connections
(Figure 1):
• Water Inlet
1/2” NPT
• Permeate (Product Water)
1/2” NPT
• Drain
1/2” NPT
When making a plumbing connection to the system,
remember to use a back-up wrench on the supporting
plumbing. Always use a good quality, approved pipe
sealant or thread seal tape on pipe threads. Be careful
not to get the pipe sealant inside the pipe when making
the connections.
Do NOT over tighten the connections. It is recom
-
mended that plastic fittings be used when connecting to
the plastic connections of the system. This will reduce
the possibility of cracking the connections due to over-
tightening.
If soldered plumbing is used, do NOT apply heat to,
or near, the filtration system. The use of union (O-ring
seal) connections is highly recommended for ease of
installation and future servicing.
cautIOn
this equipment is to be installed to comply with
the basic plumbing code of the building Officials
and code administrators, Inc. (bOca) and the
food service sanitation manual of the food and
Drug administration (fDa).
cautIOn
water pressure must not exceed 100 psig (690
kpa). to reduce water pressure, install a water
pressure regulator and set water pressure to suit
application. note that the trans membrane pres-
sure must not exceed 45 psi (310 kpa).
equipment setup
General
When placing the unit into service, pay attention to the
following guidelines:
• Do NOT immerse cord or plug in water.
• Keep cord away from heated surfaces.
suGGesteD tOOls anD supplIes fOr InstallatIOn
The following tools and supplies are suggested to make
the installation easier:
• Screwdriver
• Drill with bits
• Tape measure
• Pipe wrenches
• Adjustable wrenches
• level
• Two gallon bucket
• Pipe dope or thread seal tape
• Fresh 5 1/4% liquid chlorine
bleach
electrIcal
Ensure that the line voltage corresponds to the stated
voltage on the units specification label. Make sure that
the plug on the power cord from the system and the
outlet match. For proper operation, and to ensure the
highest quality water from the system, make sure that
the system is not connected to a switched electrical
outlet.
ImpOrtant
commonwealth of massachusetts plumbing code
248 cmr shall be adhered to. the use of saddle
valves are not permitted, please consult your local
plumber.