background image

UF-216CC water Filtration system

8

A.J. Antunes & Co.

P/N 1011135 Rev. A 03/12

unpacking

  1.  Remove the system and all packing materials 

from the shipping carton.

  2.  Remove all packing materials and protective  

coverings from the system

  3.  Remove the information packet. To prevent any 

delay in obtaining warranty coverage, fill out and 

mail the warranty card.

nOte: If any parts are damaged, contact a.J. 

antunes & co. ImmeDIately at 1-800-253-2991 or 

1-630-784-1000.

InstallatIOn

plumbInG

nOte: this unit is designed to use tap water not to 

exceed 100°f (38°c) or 100 psig (690 kpa).

The UF-216CC system uses the following connections 

(Figure 1):

 

•  Water Inlet  

 

 

1/2” NPT

 

•  Permeate (Product Water) 

1/2” NPT

 

•  Drain   

 

 

1/2” NPT

When making a plumbing connection to the system, 

remember to use a back-up wrench on the supporting 

plumbing.  Always use a good quality, approved pipe 

sealant or thread seal tape on pipe threads.  Be careful 

not to get the pipe sealant inside the pipe when making 

the connections.  

Do NOT over tighten the connections.  It is recom

-

mended that plastic fittings be used when connecting to 

the plastic connections of the system.  This will reduce 

the possibility of  cracking the connections due to over-

tightening.  
If soldered plumbing is used, do NOT apply heat to, 

or near, the filtration system.  The use of union (O-ring 

seal) connections is highly recommended for ease of 

installation and future servicing.

cautIOn

this equipment is to be installed to comply with 

the basic plumbing code of the building Officials 

and code administrators, Inc. (bOca) and the 

food service sanitation manual of the food and 

Drug administration (fDa).

cautIOn

water pressure must not exceed 100 psig (690 

kpa).  to reduce water pressure, install a water 

pressure regulator and set water pressure to suit 

application.  note that the trans membrane pres-

sure must not exceed 45 psi (310 kpa).

equipment setup

General

When placing the unit into service, pay attention to the 

following guidelines:

  •  Do NOT immerse cord or plug in water.

  •  Keep cord away from heated surfaces.

suGGesteD tOOls anD supplIes fOr InstallatIOn

The following tools and supplies are suggested to make 

the installation easier:

•  Screwdriver

 

•  Drill with bits

 

•  Tape measure

 

•  Pipe wrenches

 

•  Adjustable wrenches

 

•  level

 

•  Two gallon bucket

 

•  Pipe dope or thread seal tape

 

•  Fresh 5 1/4% liquid chlorine  

 bleach

electrIcal

Ensure that the line voltage corresponds to the stated 

voltage on the units specification label. Make sure that 

the plug on the power cord from the system and the 

outlet match. For proper operation, and to ensure the 

highest quality water from the system, make sure that 

the system is not connected to a switched electrical 

outlet.

ImpOrtant

commonwealth of massachusetts plumbing code 

248 cmr shall be adhered to. the use of saddle 

valves are not permitted, please consult your local 

plumber.

Summary of Contents for UF-216CC

Page 1: ...P N 1011135 Rev A 03 12 UF 216CC owner s manual water filtration system Manufacturing Numbers 9700407 www ajantunes com...

Page 2: ...ct the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under war...

Page 3: ...information in the next column and have it handy when calling for assistance The serial number is on the specification plate located on the unit Purchased From Date of Purchase Model No Serial No Mfg...

Page 4: ...rical shock hazard Failure to follow these instructions could result in serious injury or death Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by...

Page 5: ...240 10 0 8 50 60 Model Mfg No Width A Depth B Height C UF 216CC 9700407 14 26 cm 7 18 cm 26 66 cm Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply...

Page 6: ...er Filtration system 6 A J Antunes Co P N 1011135 Rev A 03 12 Drain Pulse Controller Specifications continued Flush Button Filter Housing Figure 1 Components Permeate Outlet Carbon Housing Inlet Mount...

Page 7: ...the system will NOT flush This could cause the Ultra Filter to plug premature ly and may void the warranty The flush is automated by the controller to last 10 seconds and take place in one hour interv...

Page 8: ...al connections is highly recommended for ease of installation and future servicing Caution This equipment is to be installed to comply with the basic plumbing code of the Building Officials and Code A...

Page 9: ...studs or with the appropriate heavy duty mounting hardware The system is pre assembled to a Mounting Bracket The Mounting Bracket has mounting holes to secure the bottom of the system to the wall Inl...

Page 10: ...tion This will help prevent possible contamination of the filter system due to other equipment downstream The check valve not supplied should be mounted close to the system outlet and sized properly f...

Page 11: ...of the system Sanitizing the System and Lines The plumbing must be sanitized to eliminate possible contamination that may have occurred during the instal lation process One ounce 30 ml of liquid chlo...

Page 12: ...a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element Housing 3 Direct water from the Permeate Outlet to a drain 4 Turn on the water to the...

Page 13: ...bows and fittings to the new cartridge Make sure the drain solenoid valve is attached to the drain end and the inlet strainer is attached to the inlet end NOTE Do NOT overtighten the elbows on to the...

Page 14: ...n approved food grade lubricant and install into the Carbon Element Housing 11 Install the new Carbon Element into the Carbon Element Housing NOTE Make sure the Gasket remains in place in the recessed...

Page 15: ...power is restored based on the interval setting selected Figure 7 Controller Flush Interval Button Hold Time Button LED Flush LED 15 minutes A 10 seconds On On 30 minutes B 10 seconds On On 45 minutes...

Page 16: ...Storage shipping solution not com pletely rinsed out of system Rinse system for a longer period of time Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing addit...

Page 17: ...1 2 0012357 Universal Pulse Controller 1 3 0012146 Power Adapter 1 4 0506230 Cartridge Bracket 1 5 0505639 Filter Housing Bracket 1 6 3080157 Screw 08 32 x 3 8 8 7 2190164 Reducing Nipple 3 4 4 8 404...

Page 18: ...UF 216CC water Filtration system 18 A J Antunes Co P N 1011135 Rev A 03 12 Notes...

Page 19: ...UF 216CC water filtration system 19 A J Antunes Co P N 1011135 Rev A 03 12 Notes...

Page 20: ...operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Reviews: