replacing the ultra filter cartridge

  1.  Open the faucet or tap closest downstream to the 

filtration system.

  2.  Close the Inlet Water Valve and allow the system 

to depressurize.

  3.  Place a bucket under the strainer at the inlet 

connection to the system. Open the strainer by 

unscrewing the cap. Water will flow out of the 

strainer as the system drains.

  4.  Press the 

flusH 

button to help drain the system.

  5.  Reattach the cap on the strainer when the water 

flow stops. Unplug the power cord.

  6.  Disconnect the Inlet Port and Drain Port 

Connections.

  7.  Disconnect the Permeate Port Connection.

  8.  Using a screwdriver, remove the screws from the 

Cartridge Bracket and set the bracket and screws 

aside.

  9.  Unscrew the elbows at the Inlet and Drain Ports of 

the cartridge. Set the elbows and fittings aside.

 10.  Using thread seal tape and pipe dope, attach the 

elbows and fittings to the new cartridge. Make 

sure the drain solenoid valve is attached to the 

drain end and the inlet strainer is attached to the 

inlet end.

nOte: Do nOt overtighten the elbows on to the 

cartridge.

  11.  Install the new cartridge with fittings attached 

using the cartridge bracket and screws from Step 8.

 12.  Inspect the O-rings and seals to ensure they 

are clean and not splitting or cut. For all O-rings 

and seals, ensure they are lubricated with an 

approved food grade lubricant acceptable for 

drinking water use.

 13.  Connect the Permeate Port Connection.

figure 5. replacing the ultra filter cartridge

cartridge 

bracket

cartridge

end cap

permeate 

port 

connection

 14.  Reattach the Inlet Port and Drain Port 

Connections.

 15.  Plug in the power cord.

 16.  Open the Inlet Water Valve and allow the system 

to pressurize.

 17.  Rinse the new Ultra Filter Cartridge before 

placing the system back into operation. Follow 

the 

rinsing the Ultra Filter Cartridge

 

and 

sanitizing the system and lines

 procedures in 

the Installation section of this manual to complete 

the cartridge change.

 18.  When rinsing is complete, repressurize the  

system.

Summary of Contents for UF-216CC

Page 1: ...P N 1011135 Rev A 03 12 UF 216CC owner s manual water filtration system Manufacturing Numbers 9700407 www ajantunes com...

Page 2: ...ct the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under war...

Page 3: ...information in the next column and have it handy when calling for assistance The serial number is on the specification plate located on the unit Purchased From Date of Purchase Model No Serial No Mfg...

Page 4: ...rical shock hazard Failure to follow these instructions could result in serious injury or death Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by...

Page 5: ...240 10 0 8 50 60 Model Mfg No Width A Depth B Height C UF 216CC 9700407 14 26 cm 7 18 cm 26 66 cm Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply...

Page 6: ...er Filtration system 6 A J Antunes Co P N 1011135 Rev A 03 12 Drain Pulse Controller Specifications continued Flush Button Filter Housing Figure 1 Components Permeate Outlet Carbon Housing Inlet Mount...

Page 7: ...the system will NOT flush This could cause the Ultra Filter to plug premature ly and may void the warranty The flush is automated by the controller to last 10 seconds and take place in one hour interv...

Page 8: ...al connections is highly recommended for ease of installation and future servicing Caution This equipment is to be installed to comply with the basic plumbing code of the Building Officials and Code A...

Page 9: ...studs or with the appropriate heavy duty mounting hardware The system is pre assembled to a Mounting Bracket The Mounting Bracket has mounting holes to secure the bottom of the system to the wall Inl...

Page 10: ...tion This will help prevent possible contamination of the filter system due to other equipment downstream The check valve not supplied should be mounted close to the system outlet and sized properly f...

Page 11: ...of the system Sanitizing the System and Lines The plumbing must be sanitized to eliminate possible contamination that may have occurred during the instal lation process One ounce 30 ml of liquid chlo...

Page 12: ...a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element Housing 3 Direct water from the Permeate Outlet to a drain 4 Turn on the water to the...

Page 13: ...bows and fittings to the new cartridge Make sure the drain solenoid valve is attached to the drain end and the inlet strainer is attached to the inlet end NOTE Do NOT overtighten the elbows on to the...

Page 14: ...n approved food grade lubricant and install into the Carbon Element Housing 11 Install the new Carbon Element into the Carbon Element Housing NOTE Make sure the Gasket remains in place in the recessed...

Page 15: ...power is restored based on the interval setting selected Figure 7 Controller Flush Interval Button Hold Time Button LED Flush LED 15 minutes A 10 seconds On On 30 minutes B 10 seconds On On 45 minutes...

Page 16: ...Storage shipping solution not com pletely rinsed out of system Rinse system for a longer period of time Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing addit...

Page 17: ...1 2 0012357 Universal Pulse Controller 1 3 0012146 Power Adapter 1 4 0506230 Cartridge Bracket 1 5 0505639 Filter Housing Bracket 1 6 3080157 Screw 08 32 x 3 8 8 7 2190164 Reducing Nipple 3 4 4 8 404...

Page 18: ...UF 216CC water Filtration system 18 A J Antunes Co P N 1011135 Rev A 03 12 Notes...

Page 19: ...UF 216CC water filtration system 19 A J Antunes Co P N 1011135 Rev A 03 12 Notes...

Page 20: ...operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Reviews: