mounting the system

The UF-216CC system comes with a Mounting Bracket 

to mount the system securely. When mounting the sys-

tem, pay attention to the following guidelines:

•  Note the location of the water supply, drain, and 

an appropriate electrical outlet when choosing a 

mounting location.

•  Allow sufficient access for cartridge replacement. 
•  Mount the system near but NOT above an appropri

-

ate electrical outlet.

•  Do NOT mount the system above any electrical 

equipment or items that may be damaged if they 

get wet.

•  Mount the system near a drain for flushing opera

-

tions.

•  Mount the system before all consumable water 

 

filtration processes.

•  Secure the Mounting Bracket into wall studs or with 

the appropriate heavy duty mounting hardware.

The system is pre-assembled to a Mounting Bracket. 

The Mounting Bracket has mounting holes to secure 

the bottom of the system to the wall.

Inlet water plumbing

The Inlet water plumbing line should be 1/2 ” NPT or 

larger. A shutoff valve (not supplied) should be installed 

in the line leading to the system. The valve should be 

mounted close to the system inlet and sized properly for 

the inlet plumbing line.
An optional “T” or Cross Fitting with cap or plug can be 

installed between the Inlet Valve and the System Inlet. 

This fitting can be used for draining and sanitizing the 

system and downstream plumbing.
The system should only be connected to the cold water 

line.
Before connecting the fitting to the System Inlet, the 

plumbing to the system must be flushed clear of all 

debris. Hold a bucket at the inlet water line and slowly 

open the Inlet Water Valve. Allow the pipe to flush until 

all debris is removed.

Summary of Contents for UF-216CC

Page 1: ...P N 1011135 Rev A 03 12 UF 216CC owner s manual water filtration system Manufacturing Numbers 9700407 www ajantunes com...

Page 2: ...ct the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under war...

Page 3: ...information in the next column and have it handy when calling for assistance The serial number is on the specification plate located on the unit Purchased From Date of Purchase Model No Serial No Mfg...

Page 4: ...rical shock hazard Failure to follow these instructions could result in serious injury or death Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by...

Page 5: ...240 10 0 8 50 60 Model Mfg No Width A Depth B Height C UF 216CC 9700407 14 26 cm 7 18 cm 26 66 cm Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply...

Page 6: ...er Filtration system 6 A J Antunes Co P N 1011135 Rev A 03 12 Drain Pulse Controller Specifications continued Flush Button Filter Housing Figure 1 Components Permeate Outlet Carbon Housing Inlet Mount...

Page 7: ...the system will NOT flush This could cause the Ultra Filter to plug premature ly and may void the warranty The flush is automated by the controller to last 10 seconds and take place in one hour interv...

Page 8: ...al connections is highly recommended for ease of installation and future servicing Caution This equipment is to be installed to comply with the basic plumbing code of the Building Officials and Code A...

Page 9: ...studs or with the appropriate heavy duty mounting hardware The system is pre assembled to a Mounting Bracket The Mounting Bracket has mounting holes to secure the bottom of the system to the wall Inl...

Page 10: ...tion This will help prevent possible contamination of the filter system due to other equipment downstream The check valve not supplied should be mounted close to the system outlet and sized properly f...

Page 11: ...of the system Sanitizing the System and Lines The plumbing must be sanitized to eliminate possible contamination that may have occurred during the instal lation process One ounce 30 ml of liquid chlo...

Page 12: ...a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element Housing 3 Direct water from the Permeate Outlet to a drain 4 Turn on the water to the...

Page 13: ...bows and fittings to the new cartridge Make sure the drain solenoid valve is attached to the drain end and the inlet strainer is attached to the inlet end NOTE Do NOT overtighten the elbows on to the...

Page 14: ...n approved food grade lubricant and install into the Carbon Element Housing 11 Install the new Carbon Element into the Carbon Element Housing NOTE Make sure the Gasket remains in place in the recessed...

Page 15: ...power is restored based on the interval setting selected Figure 7 Controller Flush Interval Button Hold Time Button LED Flush LED 15 minutes A 10 seconds On On 30 minutes B 10 seconds On On 45 minutes...

Page 16: ...Storage shipping solution not com pletely rinsed out of system Rinse system for a longer period of time Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing addit...

Page 17: ...1 2 0012357 Universal Pulse Controller 1 3 0012146 Power Adapter 1 4 0506230 Cartridge Bracket 1 5 0505639 Filter Housing Bracket 1 6 3080157 Screw 08 32 x 3 8 8 7 2190164 Reducing Nipple 3 4 4 8 404...

Page 18: ...UF 216CC water Filtration system 18 A J Antunes Co P N 1011135 Rev A 03 12 Notes...

Page 19: ...UF 216CC water filtration system 19 A J Antunes Co P N 1011135 Rev A 03 12 Notes...

Page 20: ...operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Reviews: