VHT Raptor Manual Ver. 3.1
40
05
th
June 2012
using PAN/TILT function.
2. Press the IRIS OPEN KEY to activate MENU and move to “ZONE SET”. And then, press
the IRIS OPEN KEY again.
3. Change
AREA SEL to 1.
4. Change AREA DEFINE from OFF to ON.
5. Change AREA NEW SET from OFF to ON.
6. New ZONE is activated in the centre of the screen and the ZONE can be moved using the
HEIGHT, WIDTH, PAN and TILT Menu.
7. Press the IRIS CLOSE KEY to finalise the set up.
<Caution >
Please set a MASK within -20°~80° of TILT angle.
If set a MASK at TILT angle over 90°, PAN/TILT automatically moves to the position within 90°.
5.ALARM SET
1. ALARM DISPLAY
OFF/ON
2. ALARM IN
3. ALARM OUT
<SET>
OFF/ON
4. TIME OUT
1~10sec
5.EXIT
■ ALARM DISPLAY
When signals are input from outside, the alarm number is displayed on the monitor.
■ ALARM IN
Move to the PRESET by detection of ALARM INPUT from external sensor.
How to set up PRESET
1. Move to ALARM IN, Press IRIS OPEN KEY. Below menu will follow.
1. IN1 PRESET NUM
OFF/1~128
2. EXIT
2. Set a PRESET number.
3. Move to EXIT and Press RIGHT KEY to finalise the set up.
■ TIME OUT
Set a TIME OUT for waiting time from PRESET to reactivation of TOUR after ALARM IN.
<Caution >
1. PRESET DEFINE should be set to
“ON” to activate “ALARM IN”
2. A ground of external alarm signal should be maintained at least 200ms.