WARNING
Never connect a triploar plug to a bipolar
socket! Avoid any contact between the device
(and all working equipment) and components
carrying electrical charges.
The video probe of the device must never be
used in or in the vicinity of apparatus or
equipment, which are partly or fully energized
by electric current of any type (e.g. transformers,
motors, generators, switchboards etc.). The
metallic mesh of the probe conducts electricity
and dangerous currents are transmitted during
every contact or even short-circuits can be
triggered in the plant.
The device must never be operated with
damaged video probe. There is a risk of
damage to hand due to the metallic protective
mesh (suggestion: always wear work gloves
for protection). At the same time, there is a
danger that liquids might penetrate the probe
and thereby impair the functioning permanently
or might cause a life-threatening electric
shock to the operator! Even the use of a
slightly damaged probe can quickly lead to
the total destruction of the probe due to
destruction of the light fibres or the electric
conductors lying inside. The operation of a
damaged probe is impermissible within the
area of jurisdiction of the European Union,
since the regulations on emission of electro-
magnetic radiation can no longer be adhered
to with safety.