244
PARAMETER VALUE
DESCRIPTION
direction
direct,
forward,
backward
Motor’s moving direction.
It works only if function=zoom or function=focus.
position
0~<motor_max>
Motor’s position.
It works only if function=zoom or function= focus and
direction=direct.
<motor_max> is refer to remote_focus_focus_motor_max or
remote_focus_zoom_motor_max which replied from
"function=getstatus"
steps
1 ~ <motor_max> Motor’s moving steps.
It works only if function=zoom or function=focus and
direction=forward and direction=backward.
<motor_max> is refer to remote_focus_focus_motor_max or
remote_focus_zoom_motor_max which replied from
"function=getstatus"
* This parameter is for additional fine-tune, the value is from 1 to
30.
iris
N/A
Open iris or not.
It works only if function=auto or function=scan.
© 2019 VIVOTEK INC. All Right Reserved
245
8.21 BackFocus
(capability_image_c<0~(n-1)>_remotefocus=4)
Note:
This request requires Administrator privileges.
Method:
GET/POST
Syntax:
http://<
servername
>/cgi-bin/admin/remotefocus.cgi?function=<value>[&direction=<value>]
[&position=<value>][&steps=<value>][&iris]
PARAMETER
VALUE
DESCRIPTION