background image

13

You will need to turn on both the partner camera and illuminator to precisely match the illuminated area 

with the camera's field of view. If necessary, adjust the beam angle again. 

Turn the illuminator toward the FOV of the partner camera, shift the tilt angle, and then tighten the 

screw to secure the illuminator. 

Summary of Contents for 4712123676418

Page 1: ...Installation Guide CM48 Series Vari Angle IR Illuminator Rev 1 2 QIG Part no 625037102G...

Page 2: ...o secure the illuminator to an external camera housing The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2 5 m is not expected The external flex...

Page 3: ...RTANT Class III luminaires Do not stare at the operating light source This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible...

Page 4: ...4 160mm 6 3 220mm 8 7 73mm 2 9 103 8mm 4 1 134 6mm 5 3 61 5mm 2 4 164 6mm 6 5 59 5mm 2 3 43mm 1 7 43mm 1 7 59mm 2 3 32mm 1 3 Mechanical Drawings 134 M6x1 4 64 29 3 8 2 30 82 Standard Small U bracket...

Page 5: ...r external camera housing U bracket Waterproof cover for angle selector Optional mounting points for U bracket Light sensor Combo cable Dehumidifier membrane Reserved Mounting holes Unit Weight 2 1KG...

Page 6: ...ientation Use the included allen wrench to attach and adjust the U bracket to your needs at the installation site It is highly recommended that the illuminator should be installed at a position higher...

Page 7: ...e of the allen wrench to turn the beam angle to an estimated illumination distance e g 200 meters See the tables on the next page for how to do it You may forget your current beam angle configuration...

Page 8: ...9 150 77 6 212 1 109 7 259 8 134 4 3 27 158 75 9 223 4 107 3 273 7 131 4 4 20 200 70 5 282 8 99 7 346 4 122 2 Counter clockwide Narrower Clockwide Wider The factory default for the beam angle selector...

Page 9: ...tance m Width m Distance m Width m 0 120 45 155 9 63 6 220 5 77 9 270 0 1 105 50 130 3 70 7 184 3 86 6 225 7 2 90 55 110 0 77 8 155 6 95 3 190 5 Counter clockwide Narrower Clockwide Wider Counter cloc...

Page 10: ...4 57 9 54 3 81 8 66 5 100 2 3 66 40 2 52 2 56 9 73 8 69 6 90 4 4 63 41 4 50 7 58 5 71 8 71 7 87 9 5 60 42 6 49 2 60 2 69 6 73 8 85 2 6 55 45 46 9 63 6 66 3 77 9 81 1 7 52 47 4 46 2 67 0 65 4 82 1 80 1...

Page 11: ...11 Select a position at the installation site e g under a hanging roof You can use the alignment sticker and start drilling a hole on the roof Apply the included grip sticker to the U bracket...

Page 12: ...hor Hammer the anchor in user supplied M6 anchors are recommended Secure the U bracket to it such as securing it using the bolt on a threaded pole Secure the illuminator to bracket using the hex socke...

Page 13: ...illuminator to precisely match the illuminated area with the camera s field of view If necessary adjust the beam angle again Turn the illuminator toward the FOV of the partner camera shift the tilt an...

Page 14: ...ntrol Dry contact Logic level 1 Open LED off Logic level 0 Close to GND LED on Wet contact Logic level 1 4V 40 V LED off Logic level 0 0 8V MAX LED on DI Yellow 26AWG Ground DO Purple 26AWG Light sens...

Page 15: ...Green Yellow wires This mode means that CaMate illuminator On Off control is triggered by camera or other alarm system User can decide using the appropriate dry wet contacts depending on wiring condit...

Page 16: ...ent must be under 100mA DO Bule GND Light sensor status output 1 Open Day 2 Short Night lower than 300 lux for IR to turn ON Stand alone illuminator mode This mode means that the illuminator s On Off...

Reviews: