8
CM48I8-1040
Rotate
direction
Full circle Beam angle
Single mount
Double mount
Triple mount
Distance(m)
Width(m)
Distance(m) Width(m) Distance(m) Width(m)
0
40°
100
72.8
141.4
102.9
173.2
126.1
1
36°
107
69.5
151.3
98.3
185.3
120.4
2
30°
127
68.1
179.6
96.3
220.0
117.9
3
27°
137
65.8
193.7
93.0
237.3
113.9
4
24°
150
63.8
212.1
90.2
259.8
110.4
5
16°
206
57.9
291.3
81.9
356.8
100.3
6
15°
215
56.6
304.1
80.1
372.4
98.1
7
10°
250
43.7
353.6
61.9
433.0
75.8
Counter-clockwide
Narrower
Clockwide
Wider
CM48I8-2040
Rotate
direction
Full circle Beam angle
Single mount
Double mount
Triple mount
Distance(m)
Width(m)
Distance(m) Width(m) Distance(m) Width(m)
0
40°
120
87.4
169.7
123.5
207.8
151.3
1
36°
125
81.2
176.8
114.9
216.5
140.7
2
29°
150
77.6
212.1
109.7
259.8
134.4
3
27°
158
75.9
223.4
107.3
273.7
131.4
4
20°
200
70.5
282.8
99.7
346.4
122.2
Counter-clockwide
Narrower
Clockwide
Wider
The factory default for the beam angle selector is always at the
Widest
angle. When you turn the
selector many rounds to its widest or the narrowest position, a
rotation resistance
can be felt. That
means the mechanical stop is reached, and you should not use more force.
Refer to the tables below for the configurable IR light
beam angles
and the number of
full circles
needed to change to the preferred beam angles. Each full circle corresponds to a preset beam angle.
For example, if you need to change CM48I8-1040's beam angle to 30° (127m), turn the beam angle
selector
Counter-clockwise 2 full circles
. If you are at the narrowest angle (10°) and prefer to turn to
24°, turn 3 full circles clockwise. When done, install the waterproof cover.
X2
Width
Distance
Angle
X2
30°
36°
40°