Disassemble Capillary Sub-assembly
Unsolder the soldering points connecting the capillary
sub-assy and the other pipelines, and remove the
capillary sub-assy.
Capillary Sub-assy
12.Disassemble Compressor
Firstly unsolder the pipes connecting the compressor,
and then unscrew the three foot nuts at the compressor
to remove the compressor.
Soldered dots
Nut with washer
Operating Procedures / Photos
Disassemble 4-Way Valve
Screw off the holding nut of the 4-way valve coil and
remove the coil. Use wet cotton cloth to wrap the
4-way valve, unsold the four soldering points
connecting the 4-way valve, and remove the 4-way
valve. Be quick during the unsoldering process,
pay attention to keep the wrapping cloth wet and
do not allow the soldering flame to burn the compressor
lead-out cable. (caution: only after discharging all freon).
(Only for cooling and heating unit)
Four-way valve