3.5 TIMER ON/OFF
3.5.1 TIMER ON
3.5 .2 TIMER OFF
The system will continue to run if TIMER ON is set when the system is under ON status. If TIMER OFF is set when the system
is under OFF status, the system will start to run under preset mode upon the time for auto start.
If TIMER OFF is set when the system is under OFF status, the system will maintain its standby status upon the time for auto
stop. If the TIMER OFF is set when the system is under ON status, the system will be stopped upon the tome for auto stop.
Remote Controller Function Manual
1 Temperature Parameters
Indoor preset temperature (T
preset
)
Indoor ambient temperature (T
amb.
)
2. Basic Functions
2.1 Cooling Mode
2.
4
Heating Mode
2.3 Fan mode
2.5 Auto Mode
3 Other Control
3 .1 ON/OFF
Under this mode, indoor fan motor, swing motor will run at setting status.
Under this mode, temperature setting range will be 16-30 .
Under this mode, temperature setting range will be 16-30 .
Under this mode, temperature setting range will be 16-30 .
In this mode, the indoor fan will run at preset fan speed. When the compressor stops for outdoor unit malfunction protection,
the indoor fan will still run at preset fan speed.
2.2 Dehumidifying Mode
Indoor fan will run at low speed invariably. Swing will operate according to setting status.
Press the MODE button on the remote controller to select and display the following modes:
AUTO, COOL, DRY, FAN, HEAT,AUTO.
3.2 MODE Selection
3.4 Manual Button (ON/OFF )
If press AUTO button under off status of the unit, the unit will run under auto mode with swing.If press AUTO button under on
status of the unit,the unit will be stopped.If remote controller command
is given,the mian unit will run under the command.
In this mode, the system selects COOL, HEAT and FAN mode automatically according to the change of ambient temperature.
Protection function is the same as that in cooling and heating mode.
In heating mode, if compressor is running, indoor fan will delay to run to avoid cold air blowing. When compressor stops
blowing residual heating will enter. Blowing residual heat: In heating mode, the unit is stopped by remote controller, indoor fan
will continue to run for 60s. Fan speed can not be switched during blowing residual heat.
Applicable to:
Controller Function of Indoor Unit
Controller Function Manual
Each time the On/Off
button of the remote controller is pressed, the On/Off state will switch once.
3.3 TEMP. Setting Button
Each time
button is pressed, the set temperature will be increased or decreased by 1 .Adjusting range
is 16~30 . In AUTO mode, this button does not function.
Under this mode, temperature setting range will be 16-30 .
Summary of Contents for ACP-18CH50GEI
Page 1: ...ACP 18CH50GEI RoHS Service manual ENG ...
Page 2: ......
Page 8: ...Overall and Installing Dimension of Indoor Unit 24K Unit mm Bolt Nut Wrench ...
Page 9: ...5 5 5 5 5 Electrical Diagram ACP 18CH50GEI ...
Page 31: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit ...
Page 33: ...Exploded View of Indoor Unit ...
Page 35: ...Exploded View of Outdoor Unit ...
Page 37: ...Exploded View of Outdoor Unit ...
Page 45: ......
Page 46: ......
Page 47: ......