Disassemble Electric box
Tube sensor
Plugging connector
Clasp
unplug the plugging connector of the
indoor motor at the electric box, use
screwdriver to unscrew the screw fixing
the electric box and remove the electric box.
Disassemble cross flow fan
Take out motor, then remove the cross flow fan
from the left bearing holder. Refer to Fig.7-27
Bolts
Motor
Cross flow fan
Disassemble Evaporator
Use a screwdriver to loosen the screw (1pc) of left side,
(2pcs) of right side. Take out the evaporator with your
hands, so that the side plate clamp of evaporator falls
out from the groove. Remove the evaporator with care.
Take care to protect the connecting pipe.
Screw
Screw
Screws
Motor right clamp
Disassemble Motor
Use a screwdriver to loosen the 3 screws fixing the motor
clamp. Remove the motor clamp.
Unscrew the tighten nut which fix cross flow fan, then
can take out the motor from the cross flow fan.
Summary of Contents for ACP-18CH50GEI
Page 1: ...ACP 18CH50GEI RoHS Service manual ENG ...
Page 2: ......
Page 8: ...Overall and Installing Dimension of Indoor Unit 24K Unit mm Bolt Nut Wrench ...
Page 9: ...5 5 5 5 5 Electrical Diagram ACP 18CH50GEI ...
Page 31: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit ...
Page 33: ...Exploded View of Indoor Unit ...
Page 35: ...Exploded View of Outdoor Unit ...
Page 37: ...Exploded View of Outdoor Unit ...
Page 45: ......
Page 46: ......
Page 47: ......